![DutchWest 2478 Homeowner'S Installation And Operating Manual Download Page 17](http://html1.mh-extra.com/html/dutchwest/2478/2478_homeowners-installation-and-operating-manual_2543490017.webp)
17
Dutchwest
®
Non-Catalytic Convection Heater
30002278
6. Reposition the stove so the other front corner over-
hangs the pallet and remove the leg bolt from the
bottom of the stove. Align the leg with the bolt hole
in the bottom of the stove, and attach it with the bolt
and washer. Tighten securely.
7. Reposition the stove so the irst rear leg can be at-
tached. Attach the leg using the procedure described
in Step 6. (Fig. 21)
8. Reposition the stove so the remaining leg can be
attached. Attach it using the procedure described in
Step 6. Remove the pallet from beneath the stove.
9. Remove the (4) 1/4-20 x 3/8” hex head bolts from
the mounting bosses and attach the bottom heat
shield using the same bolts.
Carefully move the stove to its inal position. One way
to lessen the effort of moving the stove over smooth
looring is to slide it on a piece of inverted carpet. Move
it slowly to ensure the loor is not scratched.
Retighten all leg fastening hardware.
ST816
Fig. 21
Reposition stove so one rear leg can be attached.
Rheostat
Knob
Rheostat
Snapstat
Pan
Head
Screws
Fig. 23
Fan installation.
ST813
Install Lower Load Door Refractory
Open the load door and place the lower load door re-
fractory on the bottom and up against the inside of the
left end. (Fig. 22)
Fan Kit Installation
1. Secure the fan assembly to the inner back with two
(2) 1/4-20 x 3/4” hex head screws and one (1) 1/4”
star washer as shown in Figure 23.
2. Attach snapstat to the mounting holes on the un-
derside of the bottom with two (2) 1/4-20 pan head
screws.
3. Attach the rheostat to the door handle insert holder
near the front left leg. Insert the rheostat control
shaft through the handle holder hole. Install the
retaining ring and rheostat knob onto the shaft.
4. Place cables where they won’t be harmed by trafic.
5. Fan will not operate until stove reaches approxi-
mately 109°F.
Lower Load Door
Refractory
Fig. 22
Install lower load door refractory. (Cutaway view for
clariication.)
ST1191