Dustcontrol DC 3800 H Original Instructions Manual Download Page 21

DC 3800 H/5800 Turbo EX - 62 

Part No 94125-I

2016-08-31

Reservdelar 

Spare Parts 

Ersatzteile 

Pieces detachees

Recambios Varaosat 

 

Запасные

 

части

 

English

Part no 

Description

Part no 

Description

Part no 

Description

Part no 

Description

Part no 

Description

Part no 

Description

Français

Deutsch

Art. Nr. 

Benennung 

Art. Nr. 

Benennung

2107 Coupling 

socket 

 50/50

40070 Container

40172 Gasket

40453E Bottom 

fl

 ap to 

fi

 ltercl. 

40497 Wheel

40577 Axle

40578 Star 

lock

41705 

CEE Plug 16A IP67 

 5P

42024 HEPA 

fi

 lter

4202501 Fine 

fi

 lter antistatic

42031 Cyclone

42050 

Hose clamp, 59-62

42074 Top

42080 Silencers, 

compl.

42082 Base

42086 

Distance, the left 

 chassis

42366 Toggle 

fastener

42374 Top

430409 

Motor, 230/400 V 

 

50 Hz Zone 21

432116 Motor 

protection, 

 4-6A 

IP65

432127 Caster 

H=100 

 locking 

device

4429 Bottom 

hook

805502 Manometer

94125-I Original 

instructions 

 

DC 3800 H/5800 

 Turbo 

EX

942122-50 Clamping ring

Art. Nr. 

Benennung

2107 Anschlussmuffe 

 50/50

40070 Behälter

40172 Dichtung

40453E Klappe 

zu 

fi

 lterreini

 gung

40497 Rad

40577 Achse

40578 Starlock/Sicherungs-

 scheibe

41705 CEE-Stecker 

16A 

 IP67 

5P

42024 HEPA 

fi

 lter

430409 

Motor, 230/400 V 

 

50 Hz Zone 21

432116 Motorschutz, 

4-6A 

 IP65

432127 Lenkrolle, 

H=100 

 verschliessbar

4429 Bodenhaken

805502 Unterdruckmano-

 meter

94125-I Originalbetriebsanlei

 

tung DC 3800 H/

 

5800 Turbo EX

942122-50 Spannring

4202501 Fein

fi

 lter antistatisch

42031 Zyklon

42050 Schlauchschelle, 

 59-62

42074 Deckel

42080 Schalldämpfer, 

 kompl.

42082 Grundlagen

42086 Entfernung, 

links 

 Chassis

42366 Haken 

furbehälter 

42374 Deckel

2107 Raccord 

50/50

40070 Conteneur

40172 Garniture 

 d’etancheite

40453E 

Rabat inférieur au

 nettoyage 

du 

fi

 ltre

40497 Roue

40577 Essieu

40578 Rondelle 

de 

 bloquage

41705 

Prise CEE 16A IP67 

 5P

42024 HEPA 

fi

 ltre

4202501 Filtre 

Conique 

 antistatique

42031 Cyclone

42050 

Collier de serrage, 

 59-62

42074 Couvercle

42080 Silencieux, 

compl.

42082 Fondations

42086 

Distance, le châssis 

 gauche

42366 Attache

42374 Couvercle

430409 

Moteur, 230/400 V

 

50 Hz Zone 21

432116 Protection 

moteur,

 4-6A 

IP65

432127 

Castor, H = 100 ver

 rouillable

4429 

Crochet de fond

805502 

Indicateur de pres

 sion

94125-I Notice 

originale 

 

DC 3800 H/5800 

 Turbo 

EX

942122-50 Bague de support

Summary of Contents for DC 3800 H

Page 1: ...n f re anv ndning av maskinen WARNING Read the instruction manual before using the machine ACHTUNG Bitte lesen Sie die Betriebsanleitung vor Inbetriebnahme der Maschine sorgf ltig durch ATTENTION Lise...

Page 2: ...ons contenues dans cette notice Tillverkare Manufactured by Hersteller Fabriqu par Valmistaja Dustcontrol AB Box 3088 Kumla G rdsv g 14 SE 145 03 Norsborg Tel 46 8 531 940 00 Fax 46 8 531 703 05 suppo...

Page 3: ...eschreibung __________ 24 Betrieb _____________________ 24 25 Wartung____________________ 25 26 Mitgeliefertes sicherheitsrelevantes Zubeh r ______________________ 27 Gew hrleistung ________________ 2...

Page 4: ...ntering VARNING maskinen f r endast anv ndas f r uppsugning och borttagning av torrt damm F RSIKTIGHET maski nen f r endast anv ndas inomhus F RSIKTIGHET maski nen m ste f rvaras inomhus SE UPP f r da...

Page 5: ...lda material m ste ske enligt direktiven i CENE LEC TR 50404 Maskinen f r inte hanteras av barn Personer med nedsatt fysisk sensorisk eller mental f rm ga f r inte hantera maskinen utan anvis ningar o...

Page 6: ...riska delarna och potentialutj mningen av de komponenter som kommer i kontakt med damm Maskinen kan anv ndas vid temperaturer mellan 10 och 40 C DC 3800 H 5800 Turbo EX r l mplig f r allm n reng ring...

Page 7: ...uren upp repas St r m taren p r tt ocks efter repetitionen ska finfiltret bytas art nr 42398 DC 5800 Turbo EX 1 Starta maskinen 2 St ng spj llet p cyklonens inlopp 3 ppna och sedan st ng filterrensnin...

Page 8: ...Maskinen ska kopplas bort fr n eln tet vid ren g ring och underh ll Service f r aldrig utf ras i zonomr det 10 Eftersom DC 3800 H 5800 Turbo EX an v nds i explosiv milj m ste dess funktiona litet insp...

Page 9: ...underh ll Efter omkring 10 000 drift timmar ska radialt tningen mellan motorn och pumpen sm rjas med lagerfett Elmotorns lager och t tningar m ste inspekteras samtidigt De ska sm rjas och vid behov b...

Page 10: ...da No tera att om maskinen har g tt med f r stor strypning s har motorskyddet l st ut som skydd mot verhettning V nta 5 minuter terst ll genom att f rst vrida till 0 l ge och sedan till start l ge Mot...

Page 11: ...era beh llare monterad Motorn g r men maskinen H l p sugslangen Byt slang suger d ligt Igensatt filter Rensa eller byt Sugslangen f r l ng Byt slang eller smal Slangen delvis igensatt V nd slangen ell...

Page 12: ...ved adequate instruction in its use WARNING This machine should only be used for the suction and re moval of dry dusts CAUTION This machine must only be used indoors CAUTION The machine must be stored...

Page 13: ...ally filters and hoses are used No plastic sacks should be used in the dust extraction part of the ma chine Safe removal of the separated materials must take place according to the directives of CENEL...

Page 14: ...uction and removal of dust deposits Explosion protection is provided by the insulation of the electrical parts and the potential equalisation of the components that come into contact with dust The mac...

Page 15: ...OFF 4 Open the shutter valve 5 If the filter condition meter reads green work can continue If in the red pulse clean again If after several repetitions the filter condition still shows red the fine fi...

Page 16: ...om the power supply during cleaning and mainte nance Service operations should never take place in the zone area 10 Because the DC 3800 H 5800 Turbo EX is used in an explosive environment the func tio...

Page 17: ...mately 10 000 hours of operation the radial seal between the motor and the pump should be lubricated with bearing grease The bearings and seals of the electric motor must be inspected at the same time...

Page 18: ...em Fault Solution Motor will not start Power not connected Motor protection tripped Connect power Investigate why the motor has overloaded and remedy Note that if the machine has been operating with t...

Page 19: ...e and remove blockage Fit the container Motor runs but suction is poor Hole in the hose Clogged filter Hose too long or too small Hose is kinked Machine top is incorrectly fitted Dust is packed in the...

Page 20: ...dd mpare kompl 42082 Fundament 42086 Distans v nster chassi 42366 Sp nnl s 42374 Lock 430409 Motor 230 400 V 50 HZ Zon 21 432116 Motorskydd 4 6A IP65 432127 L nkhjul H 100 D 75 l sbart ESD 4429 Botten...

Page 21: ...ng 40497 Rad 40577 Achse 40578 Starlock Sicherungs scheibe 41705 CEE Stecker 16A IP67 5P 42024 HEPA filter 430409 Motor 230 400 V 50 Hz Zone 21 432116 Motorschutz 4 6A IP65 432127 Lenkrolle H 100 vers...

Page 22: ...H 5800 Turbo EX 942122 50 Abrazadera Suomi Osanro Kuvaus Osanro Kuvaus Osanro Kuvaus 2107 Liit nt muhvi 50 50 40070 S ili metalli 40172 Tiiviste 40453E Pohja l pp suodat timen puhdistus 40497 Takapy...

Page 23: ...ter 429206 Finfilter antistatiskt 432136 Motorskydd 4 W 7 10 A IP65 432155 Cyklon 432156 L nkhjul H 100 broms ESD 4383 Sp nnl s 45003 Plastlock 4942 Ljudd mpare ansl 100 300 200 7467 Beh llare 40 l f...

Page 24: ...e 42796 Chassis Griff 42799 Chassis Sackhalter 42801 Platte 42802 Chassis Teil des 432156 Rolle H 100 Bremse ESD 4383 Spannhaltung 45003 Kunststoffdeckel 4942 Schalld mpfer D 100 300 200 7467 Beh lter...

Page 25: ...X 94694 50 Anillo de bloqueo Suomi Osanro Kuvaus Osanro Kuvaus Osanro Kuvaus 3031 Jatke 100 3306 Kumi kartio 108 76 EPDM 3307 Kumi kartio 108 100 EPDM 412601 Turbopumppu 380 420 660 V 419305 Turbo Pum...

Page 26: ...etta ska maskinen m rkas Dustcontrol AB Nina Uggowitzer CEO EC Declaration of conformity We hereby declare that the DC 3800 H 5800 Turbo EX is in conformity with the following directives and standards...

Page 27: ...weise gekennzeichnet werden Dustcontrol AB Nina Uggowitzer CEO D claration CE de conformit Nous d clarons que le DC 3800 H 5800 Turbo EX est en conformit avec les standards ou documents standardis s a...

Page 28: ...tar la marca Dustcontrol AB Nina Uggowitzer CEO EY vaatimustenmukaisuusvakuutus Vakuutamme ett DC 3800 H 5800 Turbo EX t ytt seuraavien direktiivien ja standardien vaatimukset 2006 42 EY 2006 95 EY 20...

Page 29: ...No 94125 I 2016 08 31 EG DC 3800 H 5800 Turbo EX c e y pe a c a ap a 2006 42 EC 2006 95 EC 2004 108 EC 94 9 EC 3mJ ep o ep o o o e y a a a e yc po c a Dustcontrol AB Nina Uggowitzer CEO II 3D Ex tc II...

Page 30: ...ding B No 1368 Wuzhong Avenue District CN Suzhou City Jiangsu Province Tel 86 180 6800 0359 sale dustcollect cn www dustcollect cn DE Dustcontrol GmbH Siedlerstra e 2 DE 71126 G ufelden Nebringen Tel...

Reviews: