![Dustcontrol DC 3800 H Original Instructions Manual Download Page 13](http://html1.mh-extra.com/html/dustcontrol/dc-3800-h/dc-3800-h_original-instructions-manual_2543288013.webp)
DC 3800 H/5800 Turbo EX - 14
Part No 94125-I
2016-08-31
Safety Considerations
7. Care of the machine
Keep the machine clean and free of dust de-
posits. Check that the hose is undamaged and
that all seals are intact. Follow all instructions.
Keep handles dry and free of oil and grease.
8 Checking for damage
Always check the machine carefully for dam-
age before use. Any damaged parts should be
repaired by a Dustcontrol authorised service
centre.
If the mains cord is damaged, it must be re-
placed by the manufacturer, its service agent
or similarly quali
fi
ed persons, in order to avoid
a hazard. The mains cord must only be re-
placed with the speci
fi
ed type.
9.
Transportation
The container must be emptied before the
machine is transported. The front wheel has a
brake that should always be locked when the
machine is stationary.
10. Warnings
Only use accessories approved by the manu-
facturer for use with Type 22. The use of other
accessories may result in the risk of explosion.
Only antistatic or metallically conductive suc-
tion accessories may be used. The machine
could leak dust that is hazardous to health if
defective or pirated parts (especially
fi
lters and
hoses) are used. No plastic sacks should be
used in the dust-extraction part of the ma-
chine.
Safe removal of the separated materials
must take place according to the directives of
CENELEC TR 50404.
This machine must not be operated by chil-
dren. Persons with reduced physical, sensory
or mental capabilities must not operate the
machine unless they receive instruction and
supervision from a person who is responsible
for their safety. Children must be supervised to
ensure that they do not play with the machine.
Information, instructions and training in the use
of the dust-extraction machine and the dusts
to be separated should be obtained before
use.
The machine is suitable for commercial use,
for example in hotels, schools, hospitals, facto-
ries, shops, of
fi
ces and rental businesses.
Technical data
DC 3800 H Turbo EX
DC 5800 Turbo EX
HxWxL
1400x600x970 mm
1942 x 780 x 1160 mm
Weight
70 kg
approx. 170 kg
Inlet
Ø 50 mm
Ø 76 mm
Container
40 litres
40 litres
Hose length
5-20 m
5-30 m
Flow, max
260 m
3
/h
470 m
3
/h
Neg. Pressure, max
28 kPa
28 kPa
Power consumption
2.2 kW
4 kW
Fine
fi
lter, polyester, area
1.8 m
2
8.3
m
2
Degree of separation
EN 60335-2-69, Class M
99.9 %
99.9 %
Filter area, HEPA
fi
lter
1.5 m
2
2.7
m
2
Degree of separation, HEPA
fi
lter
EN 1822-1
HEPA H13
HEPA H13
EN 60335-2-69, Class H
99.995 %
99.995 %
Sound level */
< 70 dB(A)
< 75 dB(A)