FILLING OPERATIONS
Dustbane Products Limited
FILLING THE FB10
NOTE: Use clean bucket of water to fill solution tank
Do not put defoamer, solvents, spotter or
prespray chemicals in the solution tank
.
Do not allow water to spill into vacuum motor
inlet. Dry spillage from top of solution tank
before replacing recovery tank
.
CHEMICALS
Suitable Chemicals
Non-Compatible Chemicals
Alkalis
Aldehydes
Detergents
Aromatic Hydrocarbons
Hydroxides
SP Butyls
Soaps
Carbon Tetrachloride
Vinegar
Clorox*
Chlorinated Bleaches
Chlorinated Hydrocarbons
Lysol*
Methyl Ethel Ketone (MEK)
Perchorethylene (perc)
Phenolics
Trichlorethylene
D-Limonen
STEP
1
STEP
2
STEP
3
STEP
4
FILL
140°F (60°C)
RECOVERY TANK
SOLUTION
TANK
* Product Trademark Names
Remove
recovery tank
Add water
10 gal.
(37.8 ltr.)
10 – 20oz.
(296ml – 591ml)
Add cleaning
chemical
140
0
F (60
0
C)
3-5
Replace recovery
tank