WARNING!
Danger due to damaged components
Operating the product with damaged compo-
nents can result in serious injury or death.
– Check components at specified intervals for
damage.
– If you detect unusual operating sounds or any
other noticeable aspects, put the product out
of service.
– Replace damaged components promptly.
WARNING!
Danger of crushing from robot movements
Robots move at high speeds and high power. If
the robot catches hold of persons, it can cause
life-threatening injury or death.
– Make sure that no people are in the danger
zone of the robot during operation.
– Before carrying out any work:
Moving robots in maintenance position
Switch off the mains disconnecting device
on the technology cabinet.
Secure against reconnection.
4.2
Assembling bracket
WARNING!
Danger of crushing from robot movements
Robots move at high speeds and high power. If
the robot catches hold of persons, it can cause
life-threatening injury or death.
– Make sure that no people are in the danger
zone of the robot during operation.
– Before carrying out any work:
Moving robots in maintenance position
Switch off the mains disconnecting device
on the technology cabinet.
Secure against reconnection.
Personnel:
Mechanic
+ additional qualification explosion protection
Protective equipment:
Eye protection
Protective workwear
Protective gloves
Anti-Static Safety Boots
Requirements:
Hand axis is in null position.
Material supply system is switched off and
secured against reconnection.
Mains disconnecting device on the technology
cabinet is switched off and secured against
reconnection.
Fig. 3: Assembling Sleeve
Molykote D
1. Lubricate screws (4) M5 x 10.
2. Screw-on sleeve (3) into the bores (2) of the
flange plate (1) using four screws (3).
Fig. 4: Assembling bracket (example)
Molykote D
3. Fit cylindrical pin (2) into the hand axis (1).
4. Fit flange plate (3) on the cylindrical pin (2).
5. Lubricate seven screws (5) M5 x 10.
6. Bolt down flange plate (3) crosswise using
screws (5).
7. Fit cylindrical pin (4) into the flange plate (3).
Assembly
03/2019
Atomizer Connection EcoGun - MRS00004EN