MAINTENANCE AND CARE
52
Proper routine maintenance of your generator is essential for safe, economical, and trouble-free
operation. It will also help reduce air pollution.
Maintenance Schedule
Remember that this schedule is based on the assumption that your machine will be used for its
designed purpose. Sustained high-load, high-temperature operation, or use in unusually wet or
dusty conditions, will require more frequent service.
SERVICE
EVERY USE
1ST MO. OR
8 HRS.
(BREAK IN)
EVERY 3 MO. OR
50 HRS. OF
HEAVY USE
EVERY 6 MO.
OR 100 HRS. OF
NORMAL USE
EVERY 12 MO. OR
300 HRS.
EVERY 3 YRS. OR
500 HRS.
ENGINE OIL
CHECK
CHANGE
CHANGE
CHANGE
AIR CLEANER
CHECK
CHECK
CHANGE
CHANGE
SEDIMENT
CUP
CLEAN
CLEAN
SPARK PLUG
CLEAN /
ADJUST
CLEAN /
ADJUST
SPARK
ARRESTOR
CHECK
CLEAN
IDLE SPEED
CHECK /
ADJUST
VALVE
CLEARANCE
CHECK /
ADJUST
FUEL TUBE
CHECK
CHECK /
REPLACE
FUEL TANK /
FILTER
CLEAN
COMBUSTION
CHAMBER
CLEAN
WARNING
: Improper maintenance, or failure to correct a problem before operation, can
cause a malfunction in which you can be seriously injured or killed. Always follow the
inspection, maintenance recommendations, and schedules in this instruction manual.
●
Make sure the engine is off before you begin any maintenance or repairs.
●
Let the engine and exhaust system cool before touching.
●
To reduce the possibility of fire or explosion, be careful when working around
gasoline. Use only a nonflammable solvent, not gasoline, to clean parts. Keep
cigarettes, sparks, and flames away from all fuel-related parts.
Summary of Contents for DUAL FUEL HYBRID ELITE DS12000EH
Page 2: ......
Page 5: ......
Page 14: ...14 ...
Page 20: ...20 ...
Page 28: ...28 ...
Page 37: ...37 ...
Page 40: ...40 ...
Page 44: ......
Page 76: ...WIRING DIAGRAM 76 M ...
Page 77: ...77 ...
Page 83: ......
Page 84: ...5800 Ontario Mills Parkway Ontario CA 91764 United States 844 DUROMAX REV DS12000EH 06292022 ...