AC Operation
2
Turn the voltage selector switch to either position.
With the voltage selector switch in the ‘‘120/240V’’ position, you can use the 120V and 120/240V
3
Switch the AC circuit breaker ON.
4
Plug in the appliance.
Most motorized appliances require more than their rated power for startup.
AC circuit breaker or AC circuit protector to switch OFF, reduce the electrical load on the circuit, wait
a few minutes and then reset the AC circuit breaker or AC circuit protector.
AC Receptacle Selection
The generator has two separate main power producing circuits. These two circuits supply equal power
to different receptacles shown when the voltage selector switch is in the 120/240V position.
When two or more receptacles are used; prevent overloading by dividing the load between the two
power circuits.
The chart below shows the rated load in amperes that can be connected to each receptacle to balance
the generator.
Main Power Circuit
Receptacles Powered by
Each Main Circuit
Power Distribution
Main Circuit 1
2 and 5
2+5=32.5 A Rated
Main Circuit 2
1 and 4
1+4=32.5 A Rated
The table shows the specifications when the 120/240V locking plug receptacle is used for 120V.
1 Start the engine .
Do not exceed the current limit specified for any one receptacle. If an overloaded circuit causes the
The total rated ampere draw is 65A in 120V ONLY.
receptacles simultaneously. If you \ require more 120V only power, then select the "120V only" position
this will disable the 120/240V twist lock plug.