2
Turn the engine switch to the OFF position.
1 Turn the AC circuit breaker to the OFF position. Disconnect DC battery charging cables.
In normal use:
To stop the engine in an emergency, move the engine switch to the OFF position.
In an emergency:
Stopping the Engine
When the engine starts, allow the engine switch to return to the ON position
.
be recharged
.
If the speed of the starter motor drops after a period of time, it is an indication that the battery should
release the switch and wait 10 seconds before operating the starter again
.
Operating the starter motor for more than 5 seconds can damage the motor. If the engine fails to start
,
start if a load is connected.
1
Make sure that the AC circuit breaker is in the OFF position. The generator may be hard to
2 Turn the gasoline fuel valve to the "OFF" position.
3 Connect the propane gas hose to the regulator/decompression valve.
4 Connect the propane gas collar to the gas supply and then turn on the propane gas supply.
5 Press the button on top of the pressure release valve down two or three times.
3 Turn the off the propane gas supply.
i. Wait 30 seconds and then push the choke lever all the way to the "OPEN" position.
a. If the engine is warm (the unit was run recently) start with the choke half open.
6 The choke operates differently on propane gas.
b. If the engine is cold (the unit was not run recently) start with the choke "OPEN".
7 Turn the engine key switch to the START position and hold it there for 5 seconds, or until the
engine starts.
Decompression
Valve / Regulator
Connect to propane
g
as
s
up
p
l
y.