2.3
Fit and connect the maintenance unit
–
Screw the hose nozzle 10 in the cubical-shaped connection 12 of
the maintenance unit 13.
–
Remove the connecting piece 8 with the washers from the
maintenance unit 13 and replace it by the screw connection
WI-E 9.
–
Screw the maintenance unit 13 on the stand in such a way that the
water separator shows downward in a vertical direction. If you
have got the stand MG 55-3, fit the maintenance unit 13 at the
cross bar on the right beneath the drive.
–
Guide the hose coming out of the sewing machine to the new
bars 3. Cut the hose off in such a way that it is not under tension
and push it into the screw connection GD-E 6.
–
Connect the screw connection GD-E 5 and the screw connection
WI-E 9 at the maintenance unit with the remaining hose.
–
Screw the coupling box 11 on your pressure supply.
–
Put the Ideal clip 15 on the pressure line 16. Then push the
pressure line 16 on the hose nozzle 10 at the maintenance unit 13.
Secure the pressure line on the connection piece 10 by the Ideal
clip 15.
–
Plug the coupling plug 14 of the pressure line 16 in the coupling
box 11 of your pressure supply.
ATTENTION!
The operating pressure amounts to 6 bar. Check at the maintenance
unit whether 6 bar is indicated!
If necessary, adjust the pressure at the maintenance unit to 6 bar
before actuating the pneumatic foot lift.
7
GB
9
5
6
12
13
9
8
10
11
14
15
16