Note: Diagrams & Illustrations Are Not to Scale. 

Note: Diagrams & Illustrations Are Not to Scale. 

Baseplate

Co-Linear 

High Wind 

Cap

Figure 5

Flex Liners

Existing 

Masonry 

Chimney

8.  Prepare the baseplate of the Co-Linear 

High Wind Cap. If it is larger than the top of 

the chimney, cut and fold as needed for a 

perfect fit.  Do not seal in place at this time.

9.   Attach  the  flex  liner  ends  at  the  top  of 

the chimney to the Co-Linear High Wind 

Cap.  Apply high temperature silicone to the 

exhaust liner prior to connecting to the Cap.  

Secure each length of flex liner to the Co-

Linear High Wind Cap.  The small screws 

provided with the hose clamps can be used 

for extra security per length (Figure 6).

Figure 6

Silicone 

Sealant

Co-Linear 

High Wind 

Cap

Baseplate

Sheet Metal 

Screws

Figure 7

10.  Apply a bead of silicone sealant to the 

top of the masonry chimney prior to securing 

the baseplate of the Co-Linear High Wind 

Cap to the masonry chimney.  Secure Co-

Linear High Wind Cap to masonry chimney 

with suitable fasteners (one at each corners) 

and cover the heads with silicone sealant 

(Figures 6 & 7).

11. Connect both of the flex directly to the 

appliance  flue  collars  (Figure  8).  See  the 

appliance manufacturer’s instructions for 

details. Secure the two Flex Liner runs to 

the appliance. The small screws provided 

with the hose clamps can be used for extra 

security per length.   Apply high temperature 

sealant on the exhaust side.  In any case, 

make sure the Flex Liners do not sag behind 

the appliance. Finally, move the appliance 

into its appropriate place.

Figure 8

Hose Clamps

Hose 

Clamps

Sheet Metal 

Screws

Summary of Contents for DIRECT-TEMP Co-Linear Insert Kit

Page 1: ...n Instructions Venting System For Direct Vent Co Linear Gas Inserts LISTED MH27778 Co Line ar Insert Kit Selkirk Direct Vent System 2022 DIRECT TEMP Form No L950_820019494 Installation Instructions 11 08 2022 Printed in U S A ...

Page 2: ...tions of certification and may affect your homeowner s insurance and safety listing of your appliance APPLICATION This instruction applies to the Selkirk Direct Temp termination system and is intended as a supplement to the applicable Direct Temp Instructions This termination and venting system in combination with the gas appliance has been tested and listed by an accredited test agency Check the ...

Page 3: ...3 MH27778 Note Diagrams Illustrations Are Not to Scale CERTIFICATION LABEL ...

Page 4: ...ght as possible avoid unnecessary bending Due to possible snagging which may result in some Failure to follow the installation instructions could cause FIRE CARBON MONOXIDE POISONING OR DEATH If you are unsure of installation requirements call the Phone Number listed on the instructions or visit www selkirkcorp com WARNING Selkirk DIRECT TEMP Colinear Insert Kit provides a Vertical Cap with a buil...

Page 5: ...nstructions surface damage caution must be observed when lowering liner lengths into the masonry flue The top section of the masonry must be water tight to prevent moisture from entering the ma sonry chimney and causing damage Consult the local building authority for more information on how to seal the damages or unused masonry section Masonry Chimney Installation 1 Measure the distance between th...

Page 6: ...lly feeding the Flex Liner down the chimney to the bottom form an angle to line up the Flex Liner with the vent opening on the appliance Important Do not let the Flex Liner sag below the level at which it will connect to the appliance or connector This could allow hot gas to become trapped and potentially become a fire hazard The Flex Liner path should always be sloped up toward the Co Linear Cap ...

Page 7: ...o Linear High Wind Cap Baseplate Sheet Metal Screws Figure 7 10 Apply a bead of silicone sealant to the top of the masonry chimney prior to securing the baseplate of the Co Linear High Wind Cap to the masonry chimney Secure Co Linear High Wind Cap to masonry chimney with suitable fasteners one at each corners and cover the heads with silicone sealant Figures 6 7 11 Connect both of the flex directl...

Page 8: ...ppear as rust spots or streaks and in extreme cases holes These compo nents should immediately be replaced 2 Remove the cap and remove any bird nests or other foreign material 3 Check for evidences of excessive con densate such as water droplets forming in the liners and subsequently dripping out at joints Continuous condensate can cause corrosion of caps liners and fittings It may be caused by ha...

Page 9: ...tion pour les encastrables colinéaire à gaz d évacuation directe Kit colinéair e pour encastrab le Système d évacuation directe de Selkirk HOMOLOGUÉ MH27778 2022 DIRECT TEMP No Formulaire L950_820019494 Instructions d installation 11 08 2022 Imprimé aux É U ...

Page 10: ...eut affecter votre assurance d habitation et la conformité de votre appareil aux normes de sécurité Ces directives s applique au système de terminaison Selkirk Direct Temp et destinée à compléter les instructions Direct Temp correspondantes Ce système de terminaison et d évacuation en combinaison avec l appareil à gaz a été testé et répertorié par une agence de test accréditée Vérifiez la plaque s...

Page 11: ...3 MH27778 Note Les schémas et illustrations ne sont pas à l échelle ÉTIQUETTE DE CERTIFICATION ...

Page 12: ...ndant gardez la gaine flexible aussi droite que possible éviter les courbures inutiles Le non respect des instructions d installation pourrait provoquer UN INCENDIE UN EMPOISONNEMENT AU MONOXYDE DE CARBONE OU LA MORT Si vous avez quelques incertitudes concernant les exigences d Installations composer le numéro indiqué dans les instructions ou consulter notre site web au www selkirkcorp com AVERTIS...

Page 13: ...areil et pourrait en conséquence être un risque d incendie Kit encastrable 3po 3po contient 2 Longueurs 3po x 35pi 1 Capuchon colinéaire 3po 3po 1 Quincaillerie vis et colliers de serrage 1 Instructions d installation Kit encastrable 4po 3po contient 1 Longueur 4po x 35pi 1 longueur 3po x 35pi 1 Capuchon colinéaire 4po 3po 1 Quincaillerie vis et colliers de serrage 1 Instructions d installation De...

Page 14: ...la cheminée jusqu en bas former un angle pour aligner le conduit flexible avec l ouverture de l appareil Important Ne pas laisser le conduit fléchir au dessous du niveau auquel il se reliera à l appareil ou au connecteur Ceci pourrait permettre au gaz chaud d être piégé et de devenir potentiellement un risque d incendie La route du conduit flexible devrait toujours être inclinée vers le haut en di...

Page 15: ...on à grand vent colinéaire Plaque de base Vis à métaux Schéma 7 10 Appliquez un ruban de scellant à la silicone sur le dessus de la cheminée de maçonnerie avant de sécuriser la plaque de base du capuchon à grand vent colinéaire à la cheminée Appuyer fermement sur la plaque de base et sécuriser en place à l aide d attaches appropriées une à chaque coin et couvrez les têtes avec un silicone shémas 6...

Page 16: ...ent im médiatement être remplacées 2 Retirer le capuchon et vérifier qu il n y a au cune obstruction pouvant empêcher la sortie des gaz ou l entrée d air Enlever tous les nids d oiseau et toute autre obstruction 3 Vérifier que l intérieur du conduit flexible ne comporte aucune infiltration d eau telles que les évidences de condensation excessive s égouttant plus tard hors des joints La con densati...

Reviews: