background image

2

Selkirk Corporation

4460 44th Street S.E., Suite F

Grand Rapids, MI 49512

Toll Free: 1.800.VENT (8368)

[email protected]

www.selkirkcorp.com

Selkirk Canada

P.O. Box 526, Depot 1,

Hamilton, ON L8L 7X6

Toll Free: 1.888.SELKIRK (735.5475)

[email protected]

www.selkirkcorp.ca

Note: Les schémas et illustrations ne sont pas à l’échelle.

Note: Les schémas et illustrations ne sont pas à l’échelle.

UNE DES CAUSES PRINCIPALES D’INCENDIES D’ÉVENTS EST 

LE FAIT DE NE PAS MAINTENIR LE DÉGAGEMENT REQUIS 

(ESPACES D’AIR) AUX MATÉRIAUX COMBUSTIBLES.  CONSULTEZ 

LE FABRICANT DE L’APPAREIL POUR CONNAÎTRE LES 

EXIGENCES DE DÉGAGEMENT.

IMPORTANT :

Veuillez lire l’ensemble des instructions 

avant de commencer l’installation.  Une 

installation de ce produit ne respectant 

pas les instructions du présent document 

annulera la garantie du fabricant,  peut 

générer un risque d’incendie  ou d’autres 

risques pour la sécurité  et peut affecter 

votre assurance d’habitation et la 

conformité de votre appareil aux normes 

de sécurité. 

Ces directives s’applique au système 

de terminaison Selkirk Direct-Temp et 

destinée à compléter les instructions 

Direct-Temp correspondantes.  Ce 

système de terminaison et d’évacuation, 

en combinaison avec l’appareil à 

gaz, a été testé et répertorié par une 

agence  de  test  accréditée.    Vérifiez  la 

plaque signalétique et les instructions 

d’installation du fabricant de l’appareil 

pour confirmer que le kit colinéaire pour 

encastrable de Selkirk est approuvé pour 

une utilisation à l’appareil que vous avez 

choisi.

Installateur:  Il est de la plus haute importance que ces 

directives seront laissé avec le propriétaire.

Propriétaire:  Gardez les directives d’installation dans un endroit 

sécuritaire pour référence future.

TABLE DES MATIÈRES

ÉTIQUETTE DE CERTIFICATION . . . . . . . . . . .  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
INFORMATION ET AVERTISSEMENTS . . . . . . .  . . . . . . . . . . . .. .. . . . . . . . . . . . . . . . . .4-5
CONTENUE DU KIT ENCASTRABLE . . . . . . . . . . . . . . . . . .  . . . . . . .  . . . . . . . . . . . . . . 5
PLANIFICATION DE L’INSTALLATION. . . . . . . . . . . . . . . . . . .  . . . . . . . . . . . . . . . . . . . . 5
INSTALLATION DANS UNE CHEMINÉE DE MAÇONNERIE. . . . . . . . . . . . . . . . . . . . . 5-7
ENTRETIEN GÉNÉRAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

APPLICATION

Summary of Contents for DIRECT-TEMP Co-Linear Insert Kit

Page 1: ...n Instructions Venting System For Direct Vent Co Linear Gas Inserts LISTED MH27778 Co Line ar Insert Kit Selkirk Direct Vent System 2022 DIRECT TEMP Form No L950_820019494 Installation Instructions 11 08 2022 Printed in U S A ...

Page 2: ...tions of certification and may affect your homeowner s insurance and safety listing of your appliance APPLICATION This instruction applies to the Selkirk Direct Temp termination system and is intended as a supplement to the applicable Direct Temp Instructions This termination and venting system in combination with the gas appliance has been tested and listed by an accredited test agency Check the ...

Page 3: ...3 MH27778 Note Diagrams Illustrations Are Not to Scale CERTIFICATION LABEL ...

Page 4: ...ght as possible avoid unnecessary bending Due to possible snagging which may result in some Failure to follow the installation instructions could cause FIRE CARBON MONOXIDE POISONING OR DEATH If you are unsure of installation requirements call the Phone Number listed on the instructions or visit www selkirkcorp com WARNING Selkirk DIRECT TEMP Colinear Insert Kit provides a Vertical Cap with a buil...

Page 5: ...nstructions surface damage caution must be observed when lowering liner lengths into the masonry flue The top section of the masonry must be water tight to prevent moisture from entering the ma sonry chimney and causing damage Consult the local building authority for more information on how to seal the damages or unused masonry section Masonry Chimney Installation 1 Measure the distance between th...

Page 6: ...lly feeding the Flex Liner down the chimney to the bottom form an angle to line up the Flex Liner with the vent opening on the appliance Important Do not let the Flex Liner sag below the level at which it will connect to the appliance or connector This could allow hot gas to become trapped and potentially become a fire hazard The Flex Liner path should always be sloped up toward the Co Linear Cap ...

Page 7: ...o Linear High Wind Cap Baseplate Sheet Metal Screws Figure 7 10 Apply a bead of silicone sealant to the top of the masonry chimney prior to securing the baseplate of the Co Linear High Wind Cap to the masonry chimney Secure Co Linear High Wind Cap to masonry chimney with suitable fasteners one at each corners and cover the heads with silicone sealant Figures 6 7 11 Connect both of the flex directl...

Page 8: ...ppear as rust spots or streaks and in extreme cases holes These compo nents should immediately be replaced 2 Remove the cap and remove any bird nests or other foreign material 3 Check for evidences of excessive con densate such as water droplets forming in the liners and subsequently dripping out at joints Continuous condensate can cause corrosion of caps liners and fittings It may be caused by ha...

Page 9: ...tion pour les encastrables colinéaire à gaz d évacuation directe Kit colinéair e pour encastrab le Système d évacuation directe de Selkirk HOMOLOGUÉ MH27778 2022 DIRECT TEMP No Formulaire L950_820019494 Instructions d installation 11 08 2022 Imprimé aux É U ...

Page 10: ...eut affecter votre assurance d habitation et la conformité de votre appareil aux normes de sécurité Ces directives s applique au système de terminaison Selkirk Direct Temp et destinée à compléter les instructions Direct Temp correspondantes Ce système de terminaison et d évacuation en combinaison avec l appareil à gaz a été testé et répertorié par une agence de test accréditée Vérifiez la plaque s...

Page 11: ...3 MH27778 Note Les schémas et illustrations ne sont pas à l échelle ÉTIQUETTE DE CERTIFICATION ...

Page 12: ...ndant gardez la gaine flexible aussi droite que possible éviter les courbures inutiles Le non respect des instructions d installation pourrait provoquer UN INCENDIE UN EMPOISONNEMENT AU MONOXYDE DE CARBONE OU LA MORT Si vous avez quelques incertitudes concernant les exigences d Installations composer le numéro indiqué dans les instructions ou consulter notre site web au www selkirkcorp com AVERTIS...

Page 13: ...areil et pourrait en conséquence être un risque d incendie Kit encastrable 3po 3po contient 2 Longueurs 3po x 35pi 1 Capuchon colinéaire 3po 3po 1 Quincaillerie vis et colliers de serrage 1 Instructions d installation Kit encastrable 4po 3po contient 1 Longueur 4po x 35pi 1 longueur 3po x 35pi 1 Capuchon colinéaire 4po 3po 1 Quincaillerie vis et colliers de serrage 1 Instructions d installation De...

Page 14: ...la cheminée jusqu en bas former un angle pour aligner le conduit flexible avec l ouverture de l appareil Important Ne pas laisser le conduit fléchir au dessous du niveau auquel il se reliera à l appareil ou au connecteur Ceci pourrait permettre au gaz chaud d être piégé et de devenir potentiellement un risque d incendie La route du conduit flexible devrait toujours être inclinée vers le haut en di...

Page 15: ...on à grand vent colinéaire Plaque de base Vis à métaux Schéma 7 10 Appliquez un ruban de scellant à la silicone sur le dessus de la cheminée de maçonnerie avant de sécuriser la plaque de base du capuchon à grand vent colinéaire à la cheminée Appuyer fermement sur la plaque de base et sécuriser en place à l aide d attaches appropriées une à chaque coin et couvrez les têtes avec un silicone shémas 6...

Page 16: ...ent im médiatement être remplacées 2 Retirer le capuchon et vérifier qu il n y a au cune obstruction pouvant empêcher la sortie des gaz ou l entrée d air Enlever tous les nids d oiseau et toute autre obstruction 3 Vérifier que l intérieur du conduit flexible ne comporte aucune infiltration d eau telles que les évidences de condensation excessive s égouttant plus tard hors des joints La con densati...

Reviews: