7
6
Board status LED’s
“FORCE” Slide switch
“CALIBRATION” Slide switch
Status LED
Micro SD card slot
For fi rmware updates
CAN LED
Flashes when CAN communication
CAN switch
DIP switch
DLC-010 Logic Board
Logic board
DIN-rail
Terminal blocks
24VDC
Power supply
Mains connection
and circuit breaker
DLC-010 overview
OFF
OFF
ON
1 2 3
CAN switch
In case the DLC-010 is at the start or end posi-
tion of the CAN bus, make sure to switch the CAN
load switch to the right position. (termination re-
sistor)
ON
CALIBRATION slide switch
To calibrate the ‘open’ and ‘close’ position of the
cover.
Switch needs to be ON, to activate calibration
FORCE slide switch
Enables the cover to move outside of calibrated
position.
Status LED
The color of this LED indicates the operation sta-
tus.
Can also be seen from outside the housing.
For details: see page 14-15
ON
OFF
DIP switch 1
Calibration via
LinkTouch
Calibration via
Calibration Slide
Switch
DMS settings from
LinkTouch
DMS settings from
DIP switch 2 & 3
DIP switch 2
DMS activated to
open cover
NO DMS to open
cover
DIP switch 3
DMS activated to
close cover
NO DMS to close
cover