7

6

Board status LED’s

“FORCE” Slide switch

“CALIBRATION” Slide switch

Status LED

Micro SD card slot

For fi rmware updates

CAN LED

Flashes when CAN communication

CAN switch

DIP switch

DLC-010 Logic Board

Logic board

DIN-rail
Terminal blocks

24VDC
Power supply

Mains connection
and circuit breaker

DLC-010 overview

OFF

OFF

ON

1 2 3

CAN switch

In case the DLC-010 is at the start or end posi-
tion of the CAN bus, make sure to switch the CAN 
load switch to the right position. (termination re-
sistor)

ON

CALIBRATION slide switch

To calibrate the ‘open’ and ‘close’ position of the 
cover.
Switch needs to be ON, to activate calibration

FORCE slide switch

Enables the cover to move outside of calibrated 
position.

Status LED

The color of this LED indicates the operation sta-
tus.
Can also be seen from outside the housing.
For details: see page 14-15

ON

OFF

DIP switch 1

Calibration via 

LinkTouch

Calibration via 

Calibration Slide 

Switch

DMS settings from 

LinkTouch

DMS settings from 

DIP switch 2 & 3

DIP switch 2

DMS activated to 

open cover

NO DMS to open 

cover

DIP switch 3

DMS activated to 

close cover

NO DMS to close 

cover

Summary of Contents for DLC-010

Page 1: ...DLC 010 Manual LINK Cover 09 05 22...

Page 2: ...n Correction Dead Man Switch settings DLC 010 in combination with LinkTouch PLP REM 350 Installation instructions Calibration Dead Man Switch settings Operation Modes Normal Calibration Force Not Cali...

Page 3: ...as following functionalities Programmable open and close positions Local control via key switch and or remote control via LinkTouch PLP REM 350 Dead man switch mode DMS can be set to open the cover an...

Page 4: ...e right position termination re sistor ON CALIBRATION slide switch To calibrate the open and close position of the cover Switch needs to be ON to activate calibration FORCE slide switch Enables the co...

Page 5: ...the key switch and check if the motor is rotating the correct way keyswitch turned to open cover needs to open If this is not the case then swap the motor power cables see picture next page switch th...

Page 6: ...g the full calibration process This function is only possible if a cali bration was already done before When the open position is corrected the close position is changed accord ingly and the other way...

Page 7: ...ON 1 Touch the display on the LinkTouch for 3 seconds to go into the settings menu 2 Use the right arrow key to select PLP REM enter then touch the display to confirm 3 In the next menu make sure the...

Page 8: ...filtration pump is enabled when the cover is not in the cali brated open or close position DMS Dead Man Switch mode CALIBRATION The status LED blinks green The cover can be controlled locally via the...

Page 9: ...ibration or calibration correction Cover moves in the wrong direction Swap the 2 motor connections or swap motor control via LinkTouch settings menu Cover settings Calibration failed Check the motor s...

Page 10: ...VISION Specials COVER Tube COVER Wall Duct COVER Motor VISION Pro HEAT Hot Splash HEAT Sun Spring HEAT Dura i HEAT Dura Vi HEAT Dura V HEAT Dura Pro HEAT Accessories LINK Touch LINK Driver LINK Master...

Page 11: ...opulsion Systems bv Dooren 72 1785 Merchtem Belgium Tel 32 2 461 02 53 www duratech be info propulsionsystems be We reserve the rights to change all or part of the contents of this document without pr...

Reviews: