![DURAG D-FL 200 Owner'S Manual Download Page 42](http://html.mh-extra.com/html/durag/d-fl-200/d-fl-200_owners-manual_2541136042.webp)
D-FL 200 / Rev. 6
39
______________________________________________________________________________________________________
Industrie Elektronik GmbH & Co KG
Measuring head:
No.
length inside the flange
complete length
1
260 mm / 10,2 in
470 mm / 18,5 in
2
360 mm / 14,2 in
570 mm / 22,4 in
Standard
3
560 mm / 22,0 in
770 mm / 30,3 in
4
760 mm / 29,9 in
970 mm / 38,2 in
5
960 mm / 37,8 in
1170 mm / 46,1 in
Ö
To combine the measuring head and the flange pay attention that
measuring head no. and flange no. are equal !!
Flange:
Pipe 110x5 mm (4,3x0,2in)
Flange
∅
190 mm (7,5in)
Material: 1.4571 (standard)
Flange length:
Flange-No.
length of the flanges
1
235 mm / 9,2 in
2
335 mm / 13,2 in
Standard
3
535 mm / 21,1 in
4
735 mm / 28,9 in
5
935 mm / 36,8 in
Ö
To combine the measuring head and the flange pay attention that
measuring head no. and flange no. are equal !!
Purge air unit “G” for gas above dew point
Mains: 230V,
±
10%, 50Hz
Others on request
Power consumption:
0,25kW at 230V
Air volume at 0 mmWS:
app. 1,4 m³/min (49,4ft³/min)
Weight: app.
20kg
Purge air unit “E“ for gas below dew point
Mains: 200...240V,
∆
-Wiring
345...415V, Y-Wiring
50Hz … 60 Hz
Other voltage and
frequencies on request
Nominal current:
2,1A
∆
-Wiring, 1,2A Y-Wiring
Power consumption:
0,43 kW at 230V, 50Hz
Air volume at 0 mmWS:
app. 2,2 m³/min (77,7ft³/min)
Weight:
app. 30 kg
One purge air unit includes 10m (33ft) purge air hose.