PLUNGER TOOL (45)
The plunger tool (45) is used to unclog drains. Attach the plunger tool to the lance (38), place the tool firmly on the drain
and blow the steam inside the drain for a few seconds. Steam will melt away residue and remove odors.
SUCTION LANCE AND NOZZLE (58, 59)
Used for general cleaning, insert the brush/squeegee insert (60) into the suction nozzle.
MAINTENANCE
MAINTENANCE OF THE BOILER
To maintain your steam cleaner in good condition and to ensure constant performance, we recommend that you periodically clean
the boiler after every 50 hours of use or less depending on the water hardness.
CLEANING INSTRUCTIONS
WARNING: Before cleaning the boiler, please make sure that the boiler is at room temperature, that it has not been used
for at least 8 hours, and that the steam cleaner is disconnected from the power source.
1. Place the steam cleaner above a sink or a bucket. Unscrew and remove the boiler drain cap (25) using the provided Allen key.
Empty all the remaining water in the boiler. Put the boiler drain cap back on. Empty the water from the water tank (20) by the drain (21).
2. Refill the water tank with equal parts of water and white vinegar (for a maximum of 0.5 gal or 2 L).
Reconnect the steam cleaner to a power outlet and turn the steam cleaner
ON (9). Doing so will fill the boiler with the vinegar solution.
Do NOT press the boiler activation button (10).
3. Turn the steam cleaner
OFF (9), disconnect and let sit overnight.
14