50 … 72
MC • Edition 05.20 • Nº 279 663
51 … 72
M
6
Remove the working membrane M
from the
guide rod N. Check the condition of the working
membrane. If necessary, use a new working
membrane M (maintenance set 21 or 22 as
appropriate) when reassembling.
H
7
Replace the O-ring H.
Remove the safety spring L.
L
5