46 … 72
MC • Edition 05.20 • Nº 279 663
47 … 72
J
3
Loosen the nut J (M 8) using a spanner size 13.
Remove the disc from the spring K.
K
4
Remove the safety spring L.
L
5
Remove the working membrane M
from the
guide rod N. Check the condition of the working
membrane. If necessary, use a new working
membrane M (maintenance set 20 or 24 as
appropriate) when reassembling.
M
6