32 … 72
MC • Edition 05.20 • Nº 279 663
C
2
Remove the cap C.
E
Remove the adjustment spring E from the spring
chamber F.
5
B
1
Release the setpoint spring E: Unscrew the adjust
-
ing cap B counterclockwise as far as it will go.
11.4.3 Type ND, MD for 2", DN40 and DN50
6. Insert a new spring with the appropriate adjustment
range.
7. Place the washer D back on the spring.
8. Screw the adjusting nut B back into the spring dome
until the desired initial spring tension is reached. Re-fit