SPECIFICATIONS
QUALIFIED INSTALLING AGENCY
Only a qualified agency should install and
replace gas piping, gas utilization equipment
or accessories, and repair and equipment ser
-
vicing. The term “qualified agency” means any
individual, firm, corporation, or company that
either in person or through a representative
is engaged in and is responsible for:
a) Installing, testing, or replacing gas piping
or
b) Connecting, installing, testing, repairing,
or servicing equipment; that is experienced
in such work; that is familiar with all precau
-
tions required; and that has complied with
all the requirement of the authority having
jurisdiction.
PRODUCT FEATURES
Your appliance is equipped to operate on
either Natural or Propane gas. The appliance
is shipped from the factory ready for connect
-
ing to Natural gas. The appliance can easily
be converted to Propane gas by having your
qualified installer follow the instructions on
page 17 and the markings on the appliance.
Models DF450SS-G and DF450SS-L
Ignition
Electronic Ignitor
Gas Type
Natural
Propane (when converted)
Maximum Input Rating 24,000 BTU/Hr
24,000 BTU/Hr
Regulator Pressure Setting
6" W.C.
6" W.C.
Main Burner Orifice Size
2.05 mm
1.66 mm
Inlet Gas Pressure*
(inches of water)
Max. 10.5" W.C.
Max. 13" W.C.
.
Normal 7" W.C.
Normal 11 W.C.
Min. 6.5" W.C.
Min. 8" W.C.
Fireplace Weight
84.5 lbs
Shipping Weight
92.5 lbs
Assembled Dimensions (H x W x D)
31.425" x 30.25" x 16.25"
Carton Dimensions (H x W x D)
31.5" x 32.375" x 18.57"
* For purposes of input adjustment.
2 GAS OPTIONS AVAILABLE
WARNING
This conversion kit shall be installed by a qualified service
agency in accordance with the manufacturer's instructions and
all applicable codes and requirements of the Authority Having Ju
-
risdiction. If the information in these instructions is not followed
exactly, a fire, explosion or production of carbon monoxide may
result causing property damage, personal injury or loss of life.
The qualified service agency is responsible for the proper instal
-
lation of this kit. The installation is not proper and complete until
the operation of the converted appliance is checked as specified
in the manufacturer's instructions supplied with the kit.