D.8 COMPRESSOR CONTROLLER
SYMPTOMS OF THE FAULT
The refrigerator is too warm and the compressor does not run
How to Confirm this fault
Measure the voltage at the input terminals of the compressor controller. If the voltage
is more than 11.5 volts (12 volt system) or more than 22.5 volts (24 volts system) the
compressor should run. If the compressor does not run, proceed as follows.
Repair action required
1. Remove the thermostat and compressor fan wires (if fitted). From terminals T, C,
and F of the compressor controller. Fit a temporary wire between terminals T and C.
The compressor should then run.
2. If the compressor does not run, CHECK THE FUSE, in the compressor controller
again as explained on page no 69.
3. If the compressor still does not run, change the compressor controller with another
of the same model (or compressor controller specified by the system supplier) see
page 85.
4. If the compressor still does not run, the compressor controller is NOT
FAULTY.PROCEED TO THE NEXT STEP ON THE FAULT FINDING CHART No.1
Summary of Contents for VC150
Page 1: ......
Page 3: ...3 SECTION I ...
Page 4: ...4 ...
Page 24: ...24 MODULE AND BATTERY WIRING DIAGRAMS SYSTEM WIRING DIAGRAM ...
Page 25: ...25 SYSTEM WIRING DIAGRAM GENERAL LAYOUT DIAGRAM ...
Page 26: ...26 GENERAL LAYOUT DIAGRAM ELECTRICAL CIRCUIT DIAGRAM ...
Page 27: ...27 ELECTRICAL CIRCUIT DIAGRAM REFRIGERATION CIRCUIT DIAGRAM ...
Page 28: ...28 REFRIGERATION CIRCUIT DIAGRAM ...
Page 29: ...29 SECTION II ...
Page 38: ...38 ...
Page 39: ...39 ...
Page 42: ...42 ...
Page 44: ...44 ...
Page 50: ...50 ...
Page 124: ...124 ANNEX 1 COMPONENT LAYOUTS OF SOME COMMONLY USED SOLAR REFRIGERATOR ...
Page 125: ...125 ...
Page 126: ...126 ...
Page 127: ...127 ...
Page 128: ...128 ...
Page 129: ...129 ...
Page 130: ...130 ANNEX II ADDITIONAL EPI TOOL KIT NEEDED FOR PHOTOVOLTAIC REFRIGERATOR REPAIR ...
Page 136: ...136 ...
Page 137: ...137 ...