Installation and Operation of
Product Holding Cabinets
18
DO NOT USE AN EXTENSION CORD. If the product
power cord is too short, have a qualified electrician
install a three-slot receptacle (or the country specific
receptacle for International Units). This unit should be
plugged into a separate circuit with the electrical rating
as provided on the product data plate.
EXTERNAL EQUIPOTENTIAL BONDING
TERMINAL (EXPORT ONLY)
This equipment has supplemental bonding terminal. The
terminal provides an external bonding connection used
in addition to the earthing prong on the plug. The terminal
provides a connection for bonding to the equipment
enclosure. The external equipotential bonding terminal
is located on the rear outside surface of the oven, the
terminal is marked with this symbol.
: If the supply cord is damaged, it must be
replaced by a special cord assembly available from Duke
Manufacturing Co. or its service agent.
: Refer to the specifications data plate when
ordering or replacing a cord set.
STACKING UNITS
: TIP HAZARD! Do not stack
any units over two pans high
: TIP HAZARD! Do not exceed
two holding cabinets per stack.
: Do not place holding cabinet
stacks on surfaces that may easily tip over.
The FWM3-24 Product Holding Cabinet is designed to
allow limited stacking capabilities. Use these procedures
to stack FWM3-24 models.
Figure 1: Removal of Base Pan
1. Remove the Base Pan from all FWM3-24s to
stacked, except the bottom unit. The pan is held
in place by two screws on the bottom of each unit.
Figure 2: Placement of Bottom Unit
2. Place bottom unit into its final position then stack
the next unit on top. The top of the lower holding
cabinet rests inside of the base of the upper unit.
Figure 3: FWM3-24 In Stacked Arrangement
Summary of Contents for FWM 6-42 SERIES
Page 2: ...Installation and Operation of Product Holding Cabinets 2...
Page 40: ...Installation and Operation of Product Holding Cabinets 40 FWM34 4 High Schematic...
Page 42: ...Installation and Operation of Product Holding Cabinets 42...
Page 43: ...43 Installation and Operation of Product Holding Cabinets...