background image

Installation and

Operation Manual

PRODUCT HOLDING 

CABINET

Please read this manual completely before attempting 

to install, operate or service this equipment

This manual is Copyright © 2018 Duke Manufacturing Co. All rights reserved.  

Reproduction without written permission is prohibited. Duke is a registered  

trademark of the Duke Manufacturing Co.

Duke Manufacturing Co.

2305 N. Broadway

St. Louis, MO 63102

Phone: 314-231-1130

Toll Free: 1-800-735-3853

Fax: 314-231-5074

www.dukemfg.com

 P/N 156224

REV V 04/20/2018

MODELS 
FWM34-12 SERIES

FWM34-15 SERIES

FWM34-22 SERIES

FWM34-23 SERIES

FWM34-24 SERIES

FWM34-31 SERIES 

FWM34-32 SERIES 

FWM34-42 SERIES

FWM34-43 SERIES

FWM  6-42 SERIES

Summary of Contents for FWM 6-42 SERIES

Page 1: ...ction without written permission is prohibited Duke is a registered trademark of the Duke Manufacturing Co Duke Manufacturing Co 2305 N Broadway St Louis MO 63102 Phone 314 231 1130 Toll Free 1 800 73...

Page 2: ...Installation and Operation of Product Holding Cabinets 2...

Page 3: ...stments 19 Closing Checklist 19 Cleaning Instructions 19 STAINLESS STEEL CARE 19 Cleaning 19 Preserving Restoring 20 Heat Tint 20 KEYPAD PROGRAMMING 20 Power Up 21 Timer Operation 21 Time Decrement 22...

Page 4: ...pplicable portions of the National Electric Code and or other local electrical codes Failure to comply with this procedure can cause property damage injury or death Before connecting the unit to the e...

Page 5: ...ore gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance Failure to comply can cause property damage injury or death In the event of a power failure do not atte...

Page 6: ...y is required for cleaning and product changes The unique design of the Duke Product Holding Unit allows single temperature operation for all existing product groups This 180 F 82 C approved temperatu...

Page 7: ...ion Standard UL197 File KNGT E17421 Standard CSA C22 2 No 109 File KNGT7 E17421 Standard ANSI NSF 4 File TSQT E157479 Directive 2006 95 EC EN60335 1 2002 A1 A2 A11 A12 EN 60335 2 49 2003 Directive 89...

Page 8: ...5 6 5 50 Compliance Declaration Standard UL197 File KNGT E17421 Standard CSA C22 2 No 109 File KNGT7 E17421 Standard ANSI NSF 4 File TSQT E157479 Directive 2006 95 EC EN60335 1 2002 A1 A2 A11 A12 EN 6...

Page 9: ...0 50 END FRONT TOP 1 3 8 3 6 cm 2 3 4 6 9 cm 1 2 4 cm 182 9cm US US CAN GERMANY FRANCE AND UK CE UNITS 20 3 4 52 776cm 14 5 8 37 196cm 17 5 8 44 762cm Compliance Declaration Standard UL197 File KNGT...

Page 10: ...0 8 0 50 END FRONT TOP 1 3 8 3 6 cm 2 3 4 6 9 cm 1 2 4 cm 182 9cm US US CAN GERMANY FRANCE AND UK CE UNITS 14 5 8 37 196cm 28 7 8 73 495cm 17 5 8 44 762cm Compliance Declaration Standard UL197 File KN...

Page 11: ...laration Standard UL197 File KNGT E17421 Standard CSA C22 2 No 109 File KNGT7 E17421 Standard ANSI NSF 4 File TSQT E157479 Directive 2006 95 EC EN60335 1 2002 A1 A2 A11 A12 EN 60335 2 49 2003 Directiv...

Page 12: ...laration Standard UL197 File KNGT E17421 Standard CSA C22 2 No 109 File KNGT7 E17421 Standard ANSI NSF 4 File TSQT E157479 Directive 2006 95 EC EN60335 1 2002 A1 A2 A11 A12 EN 60335 2 49 2003 Directiv...

Page 13: ...0 8 0 50 Compliance Declaration Standard UL197 File KNGT E17421 Standard CSA C22 2 No 109 File KNGT7 E17421 Standard ANSI NSF 4 File TSQT E157479 Directive 2006 95 EC EN60335 1 2002 A1 A2 A11 A12 EN 6...

Page 14: ...wist Lock Plug 208V US CAN IEC 60309 3 Pin Sleeve Plug 230V GERMANY FRANCE AND UK CE UNITS 18 7 8 47 854cm 32 1 2 82 418cm 17 5 8 44 769cm Compliance Declaration Standard UL197 File KNGT E17421 Standa...

Page 15: ...V US CAN IEC 60309 3 Pin Sleeve Plug 230V GERMANY FRANCE AND UK CE UNITS AU12 15P Type I Plug 230V AS NZS 3112 AUS 32in 82 133cm 27in 68 242cm 17in 44 367cm Compliance Declaration Standard UL197 File...

Page 16: ...Standard ANSI NSF 4 File TSQT E157479 Directive 2006 95 EC EN60335 1 2002 A1 A2 A11 A12 EN 60335 2 49 2003 Directive 89 336 EEC and 2004 108 EC EN61000 3 2 EN 55014 1 EN61000 3 3 EN55014 2 WEEE RoHS...

Page 17: ...nada L4W 5N6 For CE Units the PHU must be installed in accordance with the following 1 Local codes 2 European IEC CENELEC Electrical Code UNIT PLACEMENT Donotinstalltheunitnexttooraboveheatsources suc...

Page 18: ...this symbol If the supply cord is damaged it must be replacedby aspecialcordassemblyavailablefromDuke Manufacturing Co or its service agent Refer to the specifications data plate when ordering or rep...

Page 19: ...ing of the cabinet Electrical Shock Hazard unplug the cabinet before cleaning it Do not wash with water jet or hose Bottom and sides of warmer wells are very hot and cool slowly CAUTION Do not use cau...

Page 20: ...ve film to thicken It is unsightly but is not a sign of permanent damage To remove heat tint follow the routine cleaning procedure Stubborn heat tint will require heavy duty cleaning To reduce heat ti...

Page 21: ...N unless same product presentinanotherpan thenStatusLEDwillremain non illuminated andPanDisplayalternatelyshows Time Remaining and Product Name 3 At t cook time set to 4 minutes the Status LED begins...

Page 22: ...will speed the time up 7 When the proper time is reached on the Display release the Arrow Button and after 5 seconds unit willacceptnewtimeandreturntonormaloperation Menu Mode This option is used to c...

Page 23: ...SHOWN DAYPART PROGRAMMING OPTION Display Link Hold Time Temperature Press Arrow Button repeatedly to scroll through Link Time and Temperature settings Exit Menu Mode Scroll to EXIT and press the Enter...

Page 24: ...NICAL SERVICE DEPARTMENT at 800 735 3853 Log into DukePHUwebsite www dukemfg info Unique address password is supplied at purchase If needed contact TECHNICAL SERVICE DEPARTMENT Type the assigned User...

Page 25: ...quired or if you wish for all dayparts to be the same select Day Part All Select the Cabinet Temperature Units F or C Place the curser over the well to be programmed and click to display the list of c...

Page 26: ...he appearance of the screen may vary depending on the computer settings Ensure file is saving to Duke USB flash drive P N 156218 Note Depending on computer settings you may be directed to the flash dr...

Page 27: ...the PHU cabinet s USB drive REVISING A CABINET SETTING Insert a blank jump drive into the PHU Ensure that the jump drive is blank If an HCM34 cfm file is on the jump drive it will overwrite the progra...

Page 28: ...service technician Temperature Check Procedure 1 Adigitaltemperaturemeterthathasbeencalibrated must be used to get an accurate temperature reading Use a thermocouple surface temperature probe to meas...

Page 29: ...n USB flash drive and turn unit on Wait for product temperature and or name to be displayed and remove USB flash drive NONE was programmed for only one well of a heat zone Do not use NONE unless the e...

Page 30: ...161343 S S Faceplate with Gasket Assy 2X4 2 161370 S S Faceplate with Gasket Front Assy 3X1 1 161384 S S Faceplate with Gasket Rear Assy 3X1 1 600464 KIT SS FACEPLATE RENAU FWM34 32 FRONT BARS ONLY 1...

Page 31: ...ss Left 3 High 1 1 161053 Panel Access Right 1 High 1 1 161054 Panel Access Right 2 High 1 1 1 161055 Panel Access Right 3 High 1 1 17 157744 Food Pan with Notch no handle AR AR AR AR AR AR AR 157756...

Page 32: ...1 600447 KIT SS FACEPLATE RENAU FWM34 43 FRONT AND REAR BARS 1 7 See Note Heating Element 8 12 8 157725 RTD 1000 Ohms Temperature Sensor 54 4 4 9 161432 USB Host Adapter 1 1 10 600261 Switch Lighted D...

Page 33: ...33 Installation and Operation of Product Holding Cabinets FWM34 42 FWM34 43 12 19 9 20 10 6 13 14 1 16 2 4 5 3 2 Detail A A Service Label...

Page 34: ...EPS 8 12 155753 THERMOSTAT AUXILIARY 4 13 155876 LID FOODWARMER SOLID BROILED BLACK AR 14 155873 LID FOODWARMER VENTED FRIED GRAY AR 15 653638 SCREW 1 4 20 X 3 4 16 16 600456 KIT SS FACEPLATE RENAU FW...

Page 35: ...Installation and Operation of Product Holding Cabinets 6 4 5 7 16 DETAIL A 1 3 8 2 9 10 11 12 13 14 15 19 21 A NOTE Top 2 levels use FWM3 Heater Elements Bottom 2 levels use FWM34 Heater Elements FWM6...

Page 36: ...3 2 4 POWER MODULE 1 2 RTS CTS Tx 5VDC Rx GND GND 5V DATA REAR UNITS WITH REAR DISPLAYS 12 VAC XFMR POWER SWITCH EMI FILTER VAC IN GND GRN YEL L2 L1 P2 14 P2 15 P2 1 P2 2 P2 3 RED BLK YEL USB HOST UH...

Page 37: ...YEL L2 L1 P2 14 P2 15 P2 1 P2 2 P2 3 RED BLK YEL USB HOST UHA 7 P2 18 P2 8 P2 19 P2 9 ORN YEL WHT GRN P2 10 BLK P2 20 RED 6 5 4 3 2 1 BLK BLK HEATER 1 HEATER 2 1 2 3 AUX TSTAT AUX TSTAT P2 12 P2 11 P2...

Page 38: ...D P2 P1 3 2 1 RED BLK WHT WHT RED BLK RED BLK RED BLK WHT RED RED BLK RED YEL BLK BLK Vdc GND Vdc Vdc GND GND 12V GRY 4 RED 3 GRY 11 RED 7 BLK BLK EMI FILTER CE 230V LINE LOAD BLK 23 WHT 24 BLU 21 BRN...

Page 39: ...T GRN 5VDC GND Tx Rx P2 10 BLK P2 20 RED RTS CTS 6 5 4 3 2 1 UNITS WITH REAR DISPLAYS XFMR 11 GRY 7 RED 14 GRY 10 RED 14 GRY 10 RED 12 GRY 13 GRY 8 RED BLK RED WHT 1 BLU 2 BLU 3 BLU 10 BLU 10 BLU 10 B...

Page 40: ...Installation and Operation of Product Holding Cabinets 40 FWM34 4 High Schematic...

Page 41: ...YS XFMR 11 GRY 7 RED 14 GRY 10 RED 14 GRY 10 RED 9 RED 8 RED 13 GRY 12 GRY BLK RED WHT 1 BLU 2 BLU 3 BLU 4 BLU 10 BLU 10 BLU 10 BLU 10 BLU 1 BLK 2 BLK 3 BLK 4 BLK HEATER 3 HEATER 4 R2 R1 8888 8888 888...

Page 42: ...Installation and Operation of Product Holding Cabinets 42...

Page 43: ...43 Installation and Operation of Product Holding Cabinets...

Page 44: ...Installation and Operation of Product Holding Cabinets 44 Duke Manufacturing Co 2305 N Broadway St Louis MO 63102 Phone 314 231 1130 Toll Free 1 800 735 3853 Fax 314 231 5074 www dukemfg com...

Reviews: