Service Manual for Speed Oven Model DSO 500
14
Test procedure
Check 208/240 VAC is present on the motor
power connections, wires 47 and 49, as above.
If power is not present, check incoming line volt-
age, line fuses, mechanical relays K6, K8 and
primary and secondary door switches.
If power is present at all times, the door interlock
safety system has failed. Check the mechanical
relays K6, K8 and primary and secondary door
switches.
Replacement
After removing the side and top panels and
disconnecting the power cord, the stirrer motor
power leads can be disconnected. There are
four 11/32 inch nuts securing the stirrer motor
and gearbox. Upon refitting, align the dnveshaft
of the gearbox with the head of the coupling to
the stirrer blade.
STIRRER MOTOR AND GEARBOX - NOTES
Summary of Contents for DSO 500
Page 2: ...Service Manual for Speed Oven Model DSO 500 2 ...
Page 26: ...Service Manual for Speed Oven Model DSO 500 26 SOLID STATE RELAYS NOTES ...
Page 28: ...Service Manual for Speed Oven Model DSO 500 28 MECHANICAL RELAYS AND INTERLOCK SWITCHES NOTES ...
Page 32: ...Service Manual for Speed Oven Model DSO 500 32 LINE FUSES NOTES ...
Page 34: ...Service Manual for Speed Oven Model DSO 500 34 JET PLATES NOTES ...
Page 36: ...Service Manual for Speed Oven Model DSO 500 36 CABINET COOLING FANS NOTES ...
Page 40: ...Service Manual for Speed Oven Model DSO 500 40 COOLING FAN THERMAL SWITCH NOTES ...
Page 42: ...Service Manual for Speed Oven Model DSO 500 42 KEYPAD CONTROL BOARD NOTES ...
Page 44: ...Service Manual for Speed Oven Model DSO 500 44 INVERTERS NOTES ...
Page 52: ...Service Manual for Speed Oven Model DSO 500 52 COMPONENT TESTING NOTES ...
Page 57: ...57 REPAIR PROCEDURES ...