Duevi CE818 User Manual Download Page 9

 

ELECTRONIC KEYS AND KEY READER 

The electronic keys are read by key readers. 
With the keys it is only possible to arm and disarm the system. 
 

 

 

 

BASE mode 
Each key stored is an user. 
The control panel can store up to 12 electronic keys. 
All the keys have the same privileges, can arm in Total, Partial and Disarm the system 

 

 

ADVANCED mode 
At each user can be combined one electronic key (up to 16 users) 
If the user is set as MASTER, its key will arm and disarm without restrictions. 
If the user is set as GUEST, the key arm and disarm the system according to the privileges allowed by 
the Master user. 
If the user is set as PATROL, the key bypasses/rehabilitates the Patrol zones. 

 
 

 

Electronic 

key 

Multicolour 
LED 

Key reader 

Summary of Contents for CE818

Page 1: ...1 Made in Italy CE818 User Manual 14 07 M1 5 1 H2 0 F1 41 S1 41 ENG...

Page 2: ...a GSM or PSTN communicator optional to provide you an intelligent remote alarm signalling In case of alarm the phone communicator will inform you with a vocal message or SMS allowing you even when you...

Page 3: ...485 Wired electronic keys reader CHT Transponder electronic key ASIG ASC ABASC Wired magnetic contacts DIRF DIRRPV DDT S Single and double technology indoor sensors E Wall DIRFE barriers MOSKITO F Out...

Page 4: ...to the dialler User Code Six digit code used to access to alarm system using the keyboard Coercion This function allow to obtain a silent alarm signalling in case you are forced to disarm the system...

Page 5: ...programmed time and then continue at high level During the pre alarm no SMS or vocal call are sent Sensor Device for violation detection with different technologies glass breaking intrusion door open...

Page 6: ...time the zones set for this behavior This function is useful for example to allow the access only in certain areas without disarm the system service staff Zone A zone manage all the sensors connected...

Page 7: ...oard allow to control your alarm system visualize the system status functions and other alerts arm and disarm user management visualize system events and alarms ALWAYS CHECK ON DISPLAY YOUR CORRECT OP...

Page 8: ...the user violates a zone not set as Patrol R the control panel will detect alarm When leaving the Patrol user can include again the bypassed zones or it is possible to set an auto rehabilitation time...

Page 9: ...ame privileges can arm in Total Partial and Disarm the system ADVANCED mode At each user can be combined one electronic key up to 16 users If the user is set as MASTER its key will arm and disarm with...

Page 10: ...10 BASE MODE...

Page 11: ...0 30 in case of opened doors Fixed Entry time 30 Fixed Alarm time 120 Fixed Alarm cycles From same zone 4 Fixed In same arming cycle 10 Fixed Vocal calls 1 for each telephone number Only alarm call if...

Page 12: ...GSM module installed PARTIAL ARMING To arm the system in PARTIAL mode pass twice a CHT key over a key reader A confirming beep is emitted and the GREEN LED lights solid on key reader To arm it is als...

Page 13: ...ed Sound alerts One beep to confirm disarming In case entering by zone 1 before disarm a beep series signals the Entry time 30 s LED on LET 485 OFF Control panel outputs Output 1 or 2 arming type chan...

Page 14: ...key reader is normally OFF The LED lights on to signals events LED OFF ON BLINKING Red Disarmed Off TOTAL armed Alarm memory number of last violated zone at disarming for 60 seconds Green Disarmed Off...

Page 15: ...15 ADVANCED MODE...

Page 16: ...30 Changeable Alarm time 120 Changeable Alarm cycles From same zone 4 Fixed In same arming cycle 10 Fixed Vocal calls 1 for each telephone number Only alarm call if GSM BUS PSTN installed Arming modes...

Page 17: ...emitted after that the system is active 3 A beep series for about 30 seconds exit time are emitted after that the system is active TOTAL arming Active zones All the zones enabled in Total mode but byp...

Page 18: ...ch on 4 A beep series for about 30 seconds exit time are emitted after that the system is active 3 A beep series for about 30 seconds exit time are emitted after that the system is active PARTIAL 1 ar...

Page 19: ...reader and F3 button on keyboard switch on 4 A beep series for about 30 seconds exit time are emitted after that the system is active 3 A beep series for about 30 seconds exit time are emitted after...

Page 20: ...entering by a delayed zone before disarm a beep series signals the Entry time 30 seconds Visual alerts Key reader LED off Keyboard button solid on Control p outputs Output 1 INS changes status Output...

Page 21: ...ntrol panel function is enabled when a door or window remain opened the keyboard alerts by blinking the button red If with an opened door you try to arm the system the control panel will alert with a...

Page 22: ...required 2 Digit the user code followed by 3 Alert is enabled disabled The Alert status on off is shown by the blue button on keyboard 12 32 01 06 10 Disarmed User Code User Code Digit the User Code 9...

Page 23: ...long the menu options the button to enter and or confirm a choice the button to cancel and or delete PSTN REMOTE CODE Change the Remote Code For PSTN communication for GSM Remote Code see COMBY GSM BU...

Page 24: ...his user type has not access to User menu Guest Guest user has limited access and can arm only as programmed by Master or Installer Guest user can disarm the system only if enabled This user type has...

Page 25: ...e tamper line or pass a CHT key the name of the user or key will appear on display OFF To exit from test press the button OUTPUT TEST Verify outputs and wired siren working Outputs Test Wired siren To...

Page 26: ...y OFF The LED lights on to signals events LED OFF ON BLINKING Red Normal working TOTAL armed Alarm memory at disarming for 60 s Green Normal working PARTIAL 1 armed One or more opened zones at system...

Page 27: ...ber only alarm SMS COMMANDS XXXX Remote Code Note attention to spaces insert them as indicated on table Action Command Total arming XXXX instot Partial 1 arming XXXX inspar1 Partial 2 arming XXXX insp...

Page 28: ...28...

Reviews: