ARMING / DISARMING
TOTAL ARMING
To arm the system in
TOTAL
mode, pass
once
a CHT key over a key reader.
A confirming “beep” is emitted and the RED LED lights solid on key reader.
A “beep” series for about 30 seconds (exit time) are emitted, then the system is armed.
TOTAL arming
Active zones
All (zone 1 ÷ zone 8)
The zone 1 is Delayed (Entry time = 30 s)
Sound alerts
One “beep” to confirm arming
A “beep” series during Exit time (30 s)
LED on LET-485
RED, solid on
Control panel
outputs
Output 1 (“Total armed”) changes status
Output 3 (“TC”) changes status
GSM alerts
*
SMS for “Total armed” to enabled numbers
*
If GSM module installed
PARTIAL ARMING
To arm the system in
PARTIAL
mode, pass
twice
a CHT key over a key reader.
A confirming “beep” is emitted and the GREEN LED lights solid on key reader.
To arm it is also possible to hold the key over the key reader until the GREEN LED lights on (corresponding
to Partial arming) then remove it.
A “beep” series for about 30 seconds (exit time) are emitted, then the system is armed.
PARTIAL arming
Active zones
Only zones 1 ÷ 5
Zones 6 ÷ 8 are disabled
The zone 1 is Delayed (Entry time = 30 s)
Sound alerts
One “beep” to confirm arming
A “beep” series during Exit time (30 s)
LED on LET-485
GREEN, solid on
Control panel
outputs
Output 2 (“Partial arming”) changes status
Output 3 (“TC”) changes status
GSM alerts
*
SMS for “Partial armed” to enabled numbers
*
If GSM module installed