USE OF THE PANEL
3.1.
ARMINGS
Each zone can be programmed to be associated to only one of the three arming types [T=Total, P=Partial, E=External]:
TOTAL
Zones included:
T
+
P
+
E
or
T
+
P
(if E are excluded)
PARTIAL
Zones included:
P
+
E
or
P
(if E are excluded)
EXTERNAL
Zones included:
E
(even if E are excluded from T and P armings)
IF NO SENSOR IS SET AS T, P OR E, THE CORRESPONDING ARMING IS NOT EXECUTED
The sensors programmed as EXTERNAL (E) can be excluded from Total and Partial arming:
wait for 2 minutes from the last disarming
hold down the “X” button of the control panel
the status of the inclusion/exclusion of the sensors E (“excluded
included” or “included
excluded”) changes and is displayed.
on display - at rest – changes the indication:
The control panel records and maintains the status of the exclusion that has been set. To change it repeat the procedure.
Alarm
>
High powered sound from indoor and outdoor siren. Duration: 3 minutes (can be modified)
Prealarm
>
(to enable if desired) Acoustic warning from indoor siren before the alarm. Duration: 60 seconds (can be modified)
Ring
>
(only from outdoor sensors) Acoustic warning from indoor siren. Duration: 60 seconds (can be modified)
External Zones Included
Arming
Actions of the control panel in case of violation
External Zones Ring ON
External Zones Ring OFF
Total zones
Partial zones
External zones
Total zones
Partial zones
External zones
TOTAL
Alarm
(3 minutes)
Alarm
(3 minutes)
Ring
(60 seconds)
Alarm
(3 minutes)
Alarm
(3 minutes)
Alarm
(3 minutes)
PARTIAL
Not active
Pre-alarm
(0-60 seconds)
+
Alarm
(3 minutes)
Ring
(60 seconds)
Not active
Pre-alarm
(0-60 seconds)
+
Alarm
(3 minutes)
Pre-alarm
(0-60 seconds)
+
Alarm
(3 minutes)
EXTERNAL
Not active
Not active
Ring
(60 seconds)
Not active
Not active
Pre-alarm
(0-60 seconds)
+
Alarm
(3 minutes)
12:30 06/02/16 ▄
Disarmed ▄ X
12:30 06/02/16 ▄
Disarmed ▄ O
“
O
”: the sensors E are included
in Total and Partial
“
X
”: the sensors E are excluded
from Total and Partial