14
6.13.
EXTERNAL ZONES ALARM/RING
FUNCTION VALID ONLY FOR EXTERNAL ZONES
This function allows associating a low intensity beep to the outdoor sensors instead of the normal alarm.
See the following table for the different control panel response depending on the enabled or disabled function:
EXTERNAL ZONES RING ON
EXTERNAL ZONES RING OFF
TOTAL ZONES
PARTIAL ZONES
EXTERNAL ZONES
TOTAL ZONES
PARTIAL ZONES
EXTERNAL ZONES
Beep
(60 seconds)
Alarm
(3 minutes)
1.
EXTERNAL RING = ON
> Useful when you want to program as External the zones positioned strategically in the outdoor area of the
principal area to protect, that during the detection do not generate alarm but activate a low intensity "warning" beep (60 seconds).
2.
EXTERNAL RING = OFF
> Used when you want that the programmed External zones always generate alarm.
6.14.
GSM ANTI-JAMMING
The control panel is able to detect if the module GSM is not able to establish a correct communication with the network operator due to a
jamming of the GSM signal.
The relay outputs can be combined to this event and activated in case of jamming - by which it is possible to activate an alternative communication
system (example: PSTN module, wireless bridge…) and receive a warning.
Note
: in case of no network (for example: the provide is not available at the moment, the control panel is installed where the GSM signal is
weak….) the anti-jamming does not indicate jamming, the dedicated output remains at rest.