TEMPERATURE CONTROL FUNCTION
THE THERMOSTAT FUNCTION CAN WORK ONLY IF THE TEMPERATURE PROBE (OPTIONAL) IS BEEN INSTALLED.
THE THERMOSTAT FUNCTION CAN WORK ONLY IF A RELAY OUTPUT IS PROGRAMMED AS “TEMPERATURE”.
THE CONTROL PANEL MUST BE PROPERLY CONNECTED TO THE HEATING SYSTEM THROUGH THE RELAY OUTPUT.
The control panel switches on the relay output depending on the difference of temperature between the ambient temperature (measured by
the probe) and the desired temperature (programmed by SMS).
Activation
>
Send * an SMS with the following text:
* See paragraph 11, “GSM: FUNCTIONS AND PANEL
MANAGEMENT
” for details about SMS sending.
Response
>
The thermoregulation is activated for 24 hours from the receiving of the activation SMS.
The control panel activates the relay output programmed every time the ambient temperature goes under the temperature
TT desired.
Only the first time that the temperature TT desired is reached, the control panel sends a confirmation SMS.
If, at the end of 24 hours, the temperature desired is not reached, the control panel sends a SMS informing about the
ambient current temperature.
Deactivation
>
1. At the end of the 24 hours the function is automatically deactivated.
2. Send* an SMS with the following text:
3. To exit at any time from the thermoregulation (with disarmed system) press the “
#
” button for at least 3 seconds (no
SMS):
xxxx
Remote Code
TT
Desired temperature
xxxx#temp onTT
Press
long
#
xxxx
Remote Code
xxxx#temp off