3.3.
JP1 and JP2 – EXTERNAL and INTERNAL TAMPER
JP1
(disable external tamper)
Warning
: in case external tamper is going
to be used, it is
MANDATORY
to open this
jumper
CLOSED
TAMPER DISABLED
WARNING!
In this case, to avoid working anomalies of the control
panel it is MANDATORY to not connection anything to the
TMP
terminal
OPEN
TAMPER ENABLED
JP2
(disabling internal panel tamper)
CLOSED
TAMPER DISABLED
OPEN
TAMPER ENABLED
3.4.
HOW TO OPEN THE COVER FOR MAINTENANCE
Tamper is active 24h/24 (at system armed or disarmed).
To allow maintenance, the control panel disable the tamper alarm for 2 minutes from last disarming command.
To open the cover: send a disarm command and – within 2 minutes – open the cover and exclude the tamper by
closing
JP2
or switch off the control panel with
INT1
= OFF.
After the maintenance, close the cover within 2 minutes from the opening of
JP2
or from
INT1
= ON.
3.5.
JP3 - RELAY AUX
JP3
(setting Relay AUX)
CLOSED
between 1 and 2
N.C.
CLOSED
between 2 and 3
N.A.
OPEN
n.d.
1
2
3
1
2
3
1
2
3
Summary of Contents for CE 60-3 GSM