9.21.

 

Sensors Test 

 
 
 
 
 
 
 
 
 
 
 
 

9.22.

 

GSM Test 

Before activate the GSM test it is required to program 

the first telephone number on control panel

 (by software 

ComCE603 v4.0 or SMS, see Software and User manuals). If not, the GSM test fails. The telephone number must 
be a mobile type (to perform correct calls and SMS sending tests). 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

9.23.

 

Test GPRS Contact ID 

Before activate the GPRS Contact ID test it is required to program the 

Contact ID parameters 

(only by software 

ComCE603 v4.0, see Software manual). If not, the GPRS test fails: press “

X

” button to stop and exit the test. 

 
 
 
 
 
 
 
 
 
 
 

Sensors Test

 

 

 

Sensors Test 

Briefly press the "

X

" will activate the test mode of the 

wireless sensors learned. 
It will show you the number of sensors currently memorized 
and their names. 
As each sensor is activated the control panel will beep, 
display the name of the active sensor and subtracting the 
number of remaining sensors left to be tested. 
The test is successful when the display will indicate "Number 
of sensors 00 ".

 

Quickly press the “

X

” button to activate the test mode. 

Press the “

#

” button to go on the test: 

Modem working test (Modem OK / NOT OK) 

Network Operator (operatore name) 

Modem signal (graphic bar for GSM field) 

Ask for residual credit (change YES/NO with “

O

” button) 

o

YES: credit request, visualized on display 

o

NO: next step 

GSM test (change YES/NO with “

X

” button): 

o

YES: GSM network communication test (SMS 
then VOCAL CALL to the first memory number) 
Stop the test with the “

X

” button 

o

NO: end GSM test 

Quickly press the “

X

” button to activate the test mode. 

Press the “

#

” button to go on the test: 

Modem working test (Modem OK / NOT OK) 

Network Operator (operatore name) 

Modem signal (graphic bar for GSM field) 

GPRS test (change YES/NO with “

X

” button) 

o

YES: GPRS communication test 

o

NO: stop GPRS test 

GSM Test 

 

Test GPRS Con.ID 

 

Summary of Contents for CE 60-3 GSM

Page 1: ...60 CE 60 CE 60 3 GSM 3 GSM 3 GSM 3 GSM INSTALLER MANUAL INSTALLER MANUAL INSTALLER MANUAL INSTALLER MANUAL VERSION 4 2 VERSION 4 2 VERSION 4 2 VERSION 4 2 SOFTWARE MANUAL only on CD SOFTWARE MANUAL on...

Page 2: ...NKS ETC COMMUNICATION BETWEEN THE VARIOUS COMPONENTS OF THE SYSTEM ARE THOUGH RADIOFREQUENCY BEFORE FINAL INSTALLATION BE SURE THAT PANEL COMMUNICATES CORRECTLY WITH ALL THE DEVICES COULD HAPPEN THAT...

Page 3: ...ule ANTI JAMMING GSM anti blinding protection 14 4 ACTIVATE INSTALLER MENU 15 4 1 Installer menu 15 5 DELETE MEMORY 16 6 LEARNING ACTIVATORS 17 6 1 Sirens and radio voice synthesis 18 7 LEARNING WIREL...

Page 4: ...PROGRAMMING GSM DIALLER 30 10 1 Programming telephone numbers 30 10 2 SMS PIN Code 31 10 3 Add telephone number to the control panel 31 10 4 Public emergency number 32 10 5 Deleting phone numbers 32 1...

Page 5: ...grammable Relay AUX ALARM DURATION Selectable from 10 to 180 seconds MAXIMUM NUMBER OF ALARMS MAX 4 alarms per detector during arming period MAX 10 total alarms DELAYS Programmable Entry and Exit Time...

Page 6: ...tors ex power line or other wired devices etc Protected by tamper attempting ex area under control of PIRs Best for wireless range 2 2 Wall mounting Loose the two tightening screws and open the front...

Page 7: ...ack side that are dedicated to 230 V power supply Cable path wired detectors sirens keypad connections etc Position the frame so that it overlaps the hole openings to enable wiring into the wall WARNI...

Page 8: ...arm system see section 3 WIRING DIAGRAM OF THE CONTROL PANEL Insert SIM card warning read before the following note and introduce the battery without connecting it tie up with the rubber band Slot SIM...

Page 9: ...ontacts ALWAYS execute all wired connections to the control panel with the power supply OFF no 230 V or battery After all wiring connections are done short circuit all not used wired inputs IN1 IN2 an...

Page 10: ...panel L1 Total Alarm L2 Partial Opened doors L3 230 V L1 L2 External K Data input for transponder key reader Input for mechanical key SA Positive 12 V for external siren power supply or phone dialer 2...

Page 11: ...ardware key Make a series connection between K terminal and a 2 2 k resistor and here connect the key to VS NOTICE The mechanical key ONLY allows TOTAL ARMING and DISARMING OPEN TOTAL ARMING CLOSED DI...

Page 12: ...R DISABLED OPEN TAMPER ENABLED 3 4 HOW TO OPEN THE COVER FOR MAINTENANCE Tamper is active 24h 24 at system armed or disarmed To allow maintenance the control panel disable the tamper alarm for 2 minut...

Page 13: ...trol panel Since INT1 ON about 5 seconds are necessary for starting up the system During this period of time display will be off 3 8 CN14 TEMPERATURE SENSOR CN14 temperature sensor terminal TERMINAL F...

Page 14: ...the GSM module detects jamming on the GSM signal it switches the output CN6 OptoMOS N C type the alert starts after about 20 seconds from jamming CN6 will open the output return to rest after about 30...

Page 15: ...m it emits a beep and flash This code will have no effect on the DVTR RT v2 radio keyboards Note enable the control panel to transmit its radio codes by learning an activator in position n 1 4 1 Insta...

Page 16: ...PT THE REGISTERD ALARM VOICE MESSAGGES AFTER THIS OPERATION THE CONTROL PANEL WILL BE COMPLETELY EMPTY MEANING ALL THE SENSORS REMOTE CONTROLS KEYS AND PHONE NUMBERS WILL HAVE TO BE PROGRAMMED To perf...

Page 17: ...ed an activator The 0 instead indicates a vacant location Transmit ONLY with the activator you wish to store It can be a radio controlled operation a CHT CHS key or keyboard Learning X Activator 02 If...

Page 18: ...io codes to do this an activator MUST be learned in activators memory location n 1 These codes will be transmitted for the following events Arming Disarming Start alarm Stop alarm Start maintenance St...

Page 19: ...sensor learned and automatically allocates it to the corresponding zone ex CTSR and DIRRVE to PARTIAL DIRRV to TOTAL It is possible to modify this assigment IMPORTANT NOTES IT IS NOT POSSIBLE TO ADD...

Page 20: ...signal from the sensor correctly it will confirm its memorization with an X in the place of _ If the memory is not possible the control panel will emit three beeps Learning 0 Radio Zone 02 P Once pos...

Page 21: ...X Radio Code 02 P If the control panel receives a signal from the sensor correctly it will confirm its memorization with an X in the place of _ If the memory is not possible the control panel will em...

Page 22: ...he SMS commands are xxxx temp onTT xxxx temp off for details on these SMS commands see USER S GUIDE RING AUX output is activated for 2 seconds when the control panel receives a telephone call from a n...

Page 23: ...X output switches when an alarm is detected Allowing thus the possibility of excluding the internal siren if you connect the AUX in series between the AP and the siren as in figure below Relay status...

Page 24: ...Learning 0 Activators 01 Learning Activators See LEARNING ACTIVATORS section Clock set up 10 20 01 01 12 Each pressure select HOURS MINUTES DAY MONTH YEAR Each pressure will increase the value of one...

Page 25: ...D sensor Disabled Long press changes insertion T Total P Partial E External Prog Zone I Radio Zone 01 P Prog Alert D Radio Zone 01 P Time for exit in seconds Press 1 time to start count from zero Pres...

Page 26: ...fly pressing the Radio Sabotage Yes No The control panel when armed signals an alarm for Radio Blinding if it detects anomalies and or failures on radio frequencies The signals activate about 50 secon...

Page 27: ...AY TEMPERATURE Door Control Yes Door Control Yes No The control panel runs a check on all the zones to verify if there are any opened doors at the moment it is armed and signals an abnormal situation...

Page 28: ...rol panel will beep display the name of the active sensor and subtracting the number of remaining sensors left to be tested The test is successful when the display will indicate Number of sensors 00 X...

Page 29: ...Installer Menu Press the X to exit The control panel emits a few beeps and the LED ALERT flashes until the DIP 2 is set to OFF DIP 2 Set the DIP 2 to OFF to exit the Installer Menu Clock set up 10 20...

Page 30: ...tery Status Alarm Panic Telealarm 1 X X X X X X X 2 X X X X X X X 3 X X X X X X X 4 X X X X X X X 5 Only alarm 6 Only alarm 7 Only alarm 8 Only alarm Factory settings for notices to telephone numbers...

Page 31: ...factory combination code is the same 0000 four zeros the control panel will accept commands from any mobile number that sends a command with 0000 four zeros as SMS PIN Code The SMS commands contain s...

Page 32: ...er numbers just by OMITTING the international country code Example Mr Rossi would like to program the number to the Police 0000 num 5 113 10 5 Deleting phone numbers xxxx del n To delete number memori...

Page 33: ...th an SMS example 0000 cre t 404 xxxx cre s yyyyyyyyyyy testo Rechargeable SIM with credit request done by sending an SMS to the number yyyyyyyyyyy Operator will respond with an SMS example 0000 cre s...

Page 34: ...n is disabled In disarmed mode the panel does not indicate the presence of sensors with open contacts When arming Total Partial or External there will be no signal and eventual sensors that have remai...

Page 35: ...l contact appear open at the moment of insertion the Single Contact option is disabled when the reed on board is open at the moment insertion the Single Contact is enabled Diagram of REED contacts of...

Page 36: ...ime span of 30 seconds The control panel display indicates ANALOG WIRELESS SATURATION a MODULATED DIGITAL radio signal quite similar to the work of the station has transmitted 7000 digital values in a...

Page 37: ...2 IN3 L1 L2 L3 GND K SA COM S GND PRE C NC NA OUT AUX Thermostat Piezo siren DV SIR G R V K LET MONO Relay Alarm CM2 TMP Optional K3 L1 L2 L3 K2 INS K1 C IR Sensor Alarm Not used 2 2 k Powerline Prese...

Page 38: ...ese sensors must have a NC normally closed alarm output in order to be used with this control panel For connection refer to the instructions of the sensor and the following diagram WARNING ONCE THE SE...

Page 39: ...39 CE60 3GSM Installer...

Reviews: