11.17 Winder
The winding procedure must shut off automatically when the bobbin is
filled to within approx. 0.5 mm of the bobbin edge.
Caution Risk of Injury !
Turn the main switch off.
Set the bobbin capacity only with the main switch turned off.
Correcting the bobbin capacity
–
Remove the winder cap 3 after loosening the mounting screws.
–
Loosen the clamping screw 2 slightly.
–
Set the bobbin capacity by turning the operating cam 1.
Turning in the direction of the arrow A: Decrease bobbin capacity
Turning in the direction of the arrow B: Increase bobbin capacity
–
Tighten clamping screw 2.
–
Replace the winder cap 3 again.
1 2 3
69