3.
Transport unit
3.1
Adjustment of linear guide to the table-top
Instruction and inspection
During its run, the material clamp guide 1 must always have the same
distance to the table-top surface.
–
Measure the distance between the guide and the table-top to the
left and to the right.
–
Move the guide and measure distance again.
Caution! Risk of injury!
Switch off main switch!
Adjust parallel alignment of the guide only when the sewing machine is
switched off.
Adjustment
–
Loosen screws 3 of the guide bars 2 below the table-top.
–
Align guide bars 2 parallel to the bottom side of the table top and
tighten screws 3.
–
Ensure that the material clamp guide is aligned to the surface of
the table-top.
3-
31
1
3
2