background image

16

TECHNICAL ASSISTANCE AND SPARE PARTS

Before  leaving  the  factory,  this  appliance  will  have  been  tested  and  regulated  by  expert  and  specialized
personnel in order to guarantee the best performances.
Any  repairs  or  adjustments  which  may  be  subsequently  required  may  only  be  carried  out  by  qualified
personnel with the utmost care and attention.
For  this  reason,  always  contact  your  Dealer  or  our  nearest After  Sales  Service  Center  whenever  repairs  or
adjustments are required, specifying the type of fault and the model of the appliance in your possession.
Please  also  note  that  genuine  spare  parts  are  only  available  from  our After  Sales  Service  Centers  and
authorized retail outlets.
The above data are printed on the data label put on the inferior part of the appliance and on the packing label.
The above informations give to the technical assistant the possibility to get fit spare parts and a heaven-sent
intervention. We suggest to fill the table below.

MARK: .............................................................................
MODEL: ...........................................................................
SERIES: ...........................................................................

This appliance is marked according to the European directive 2002/96/EC on Waste
Electrical and Electronic Equipment (WEEE).
This  guideline  is  the  frame  of  a  European-wide  validity  of  return  and  recycling  on
Waste Electrical and Electronic Equipment.

TECHNICAL DATA ON THE DATA LABEL

GAS MODELS

1 BURNERS

UR 4 kW

Category = III

G 30 - Butane =    30 mbar
G 31 - Propane = 30 mbar
G 20 - Natural =   20 mbar

Σ 

Qn

Gas Natural = 4.0 kW

Σ 

Qn 

Butane = 291 gr/h  (G30)

Voltage = 220-240 V ~
Frequency = 50 Hz

If with battery:

Voltage = 1.5 V

2 BURNERS

Category =III

G 30 - Butane =   30 mbar
G 31 - Propane = 30 mbar
G 20 - Natural =   20 mbar

Σ 

Qn

Gas Natural = 3.8 kW

Σ 

Qn 

Butane = 276 gr/h  (G30)

Voltage = 220-240 V ~
Frequency = 50 Hz

If with battery:

Voltage = 1.5 V 

1 BURNERS

5 kW DUAL

Category = III

G 30 - Butane =    30 mbar
G 31 - Propane = 30 mbar
G 20 - Natural =   20 mbar

Σ 

Qn

Gas Natural = 5.0 kW

Σ

Qn Gas Butane = 4.75 kW

Σ 

Qn 

Butane = 345 gr/h  (G30)

Voltage = 220-240 V ~
Frequency = 50 Hz

If with battery:

Voltage = 1.5 V 

Summary of Contents for GD-Z01

Page 1: ...2016 rev 00 Dear Customer thank you for having purchased one of our products We are certain that this new modern functional and practical appliance built with the very highest quality materials will m...

Page 2: ...tic use only and it employment by private person WARNING Children less than 8 years of age shall be kept away unless continuously supervised This appliance can be used by children aged from 8 years an...

Page 3: ...he possibility to light either the inner flame only or the whole burner inner and outer flame at the same time LIGHTING AND USING THE DUAL BURNER Stand the pan on the burner before lighting Despite be...

Page 4: ...handles are correctly positioned and supervise the cooking of foods in oil and fat as these are highly flammable Do not use sprays near the appliance during use Do not drag pans across the glass hob a...

Page 5: ...sposing of it make it inoperative in conformity with current law on the protection of health and the prevention of environmental pollution by making its dangerous parts harmless especially for childre...

Page 6: ...time Do not clean using abrasive metal scourers powder abrasives or corrosive sprays WARNINGS when reassembling the components observe the following recommendations check that the holes in the burner...

Page 7: ...In case of doubt do not use the appliance and contact qualified personnel Never leave the packaging materials cardboard bags polystyrene foam nails etc within children s reach since they could become...

Page 8: ...from the seal and set the plate into the hole made in the cabinet Position the hob in the hole in the unit and fasten it in place using the appropriate screws F and the fastening hooks G fig 11 When...

Page 9: ...w or on a wall facing outside see fig 4 This must be activated at the same time as the appliance see fig 5 so long as the specifications in the provisions in force are strictly complied with 7 GAS CON...

Page 10: ...ected straight to the electricity main Install an omnipolar circuit breaker between the appliance and the electricity main This circuit breaker should be sized according to the load rating of the appl...

Page 11: ...ral edge of the hot plate The ends of the strips must fit together without overlapping Evenly and securely fix the seal to the cooktop pressing into place with the fingers and remove the strip of prot...

Page 12: ...C inside the shaft of the tap fig 13 A Turn the throttle screw to the right or left until the burner flame has been adequately regulated to the Reduced rate position The flame should not be too low t...

Page 13: ...s the heat inputs of the burners the diameter of the injectors and the working pressures of the various types of gas CONVERSIONS BURNER ARRANGEMENT ON THE COOKTOP FIG 14 BURNERS GAS NORMAL PRESSURE mb...

Page 14: ...tiff to operate it must be immediately greased in compliance with the following instructions remove the tap Clean the cone and its housing using a cloth soaked in diluent Lightly spread the cone with...

Page 15: ...e should leave the ground wire longer than the phase B conductors fig 20 and comply with the recommendations given in paragraph 8 FIG 20 In case of failure or cut in the cable please move away from th...

Page 16: ...tant the possibility to get fit spare parts and a heaven sent intervention We suggest to fill the table below MARK MODEL SERIES This appliance is marked according to the European directive 2002 96 EC...