5. Electronical installation
a. Installer/User mode:
Zone designations
You need to take account of zone designations if you are utilising an integrated
2-zone system.
Zone 1 is the bevelled side of the DucoBox Energy Premium in each case.
b. Pairing control components with the DucoBox Energy Premium
1. Activate advanced mode:
• Scroll down to ADVANCED and press enter.
• Enter the installer’s code 9876 and press enter.
2. Go to the INSTALLATION menu.