background image

Page 21

DUCATI

 products are guaranteed for 

24 

months from purchase date, for manufacture or material defects. In case of repair, the

product shall be returned to the  to one of our authorised after-sale centres. The authorised technical assistance centres are the
only acknowledged suitable to carry out repairs under guarantee.  In case of difficulties, or to get the  after sale offices of your
country  please address to:

DHA

 Srl  Via 

Cassani snc

 1  - 

43036

 

Fidenza

 (

PR

) ITA LY

Tel. +39/0

524

/

527967

    

mob.+39/335/1022019

      info@

ducatihome

.it     www. 

ducatihome

 . i t

Guarantee conditions
1.The guarantee is accepted only the demands  presented with the invoice or coupon proving the purchase; no alteration or can-
cellation shall be on the certificate.
2.

DUCATI 

obligations are limited to the repair or, at its own discretion, to the defective parts replacement.

3.The product guarantee shall immediately decay  if the product is modified and adapted to technical and safety norms diff e r e n t
from the ones in force in the country the product was conceived and manufactured for. 
No refund is foreseen for damages deriving from the above-mentioned modifications.
4.The guarantee does not cover:
a) Periodical checks, maintenance, repairs or replacement of worn out parts.
b) Transport, handling or installation costs relating to this product.
c) Improper use, mistakes in the operation and incorrect installation.
d) Damages caused by fire, water, natural phenomena, storms, incorrect power supply, or any other cause not depending on the

m a n u f a c t u r e r.
5.This guarantee neither influence the rights of the customers envisaged by law, according to the national applicable laws, nor
the rights of the customer towards the reseller deriving from the purchase contract. 
In case there were no national applicable laws, this guarantee shall be the only safeguard for the customer and neither the
manufacturer nor his distributor will be responsible for accidental or indirect damage to their own products deriving from the
infringement guarantee conditions.

16.Warranty & After sale service 

830

830

829

829

2 x 821

992014

835

CTH29S

810

811

832

828

834

809

831

2 x812

829

RAIL SET

contents:

FIXING SET

contents:

BELT SET

contents:

transformer 230V

belt pulley

8

9

00T/ belt/ roll

Complete  garage
motor  head with elec-
tronic panel, motor
and transformer

compleete  motor 

825/R117

R403 UE

826

17. Spare parts

SW5000 SW6500

SW7950

6025/5

SW7012

SW7500

Remote control  key switch

radio key pad wide angle

mirror

external antenna
with 5 m cable

Blinker

photo beam

6203 rolling 

992012

Canopy arm

18. Extra Optional accessories

How to order spare parts or optional accessories:

 

shop online : 

www.

ducatihome

.it

Summary of Contents for 8500 SF

Page 1: ...Sectional door max h 2 15 m max h 2 30 m Min 5 cm Power 230 V 50 Hz 8 24 V dc Gear 11 18 sec Opening time WARNING Carefully read this mounting instruction before installation In case you should requi...

Page 2: ...s Installation Scheme 7 9 5 Assembly instructions 10 12 6 Fixing instructions 13 14 7 Manual release 15 8 230V power supply 16 9 Remote control coding 17 10 Power adjustment 17 11 Electronic board CTH...

Page 3: ...all ropes connected to garage door before installing and operating garage door opener to avid entanglement To prevent damage to garage door and opener Always disable locks before installing and opera...

Page 4: ...t of garage door travel limits will interfere with pro per operation of safety reversal system Too much force on garage door will interfere with proper operation of safety reversal system Never increa...

Page 5: ...board CTR29S receiver and transformer One rolling code 2 channels radio transmittent 433 92 Mhz Belt drive 270 cm U iron rail 3 x 90cm with 2 connectors Manual unlocking device from inside outside Mo...

Page 6: ...separately Draw 2 Draw 3 Draw 4 Use the 2 standard door bra kets to connect the trolley to the door trolley standard door brakets standard door braket sectional door shaft 992014 Use 1 standard door...

Page 7: ...e pur chased separately as optional safety device ceiling rail To fix the rail of the garage door opener a minimal distance of 5 cm is needed between ceiling and door And a minimal distance of 1cm is...

Page 8: ...Page 8 Installation scheme Wall mount this zone must be strong and reinforced with an iron plate if needed Draw 7...

Page 9: ...p plied parts 821 CAUTION to prevent injury from pinching keep hands and fingers away from the joints while assembling the rail to avoid serious injury to fingers from moving garage door opener always...

Page 10: ...ley and around the pulley Assemble the 3 elements of the rail part 829 by fitting them into the 2 rail braces part 830 See draw 8 10 The pulley and the trolley are supplyed pre assembled Draw 11 Draw...

Page 11: ...ate as showed on draw 13 14 WARNING The securing plate must connect the belt in a specific position on the side opposite to the unlocking plug fixed on the trolley and between the trolley and the pull...

Page 12: ...rews draw 18 Insert the U rail into the plate through the guides until it stops draw 19 20 NOW your garage door opener is full mounted and ready to be fixed to the door Draw 19 Draw 18 Draw 20 Draw 21...

Page 13: ...sory 992012 up and over doors 6 step Motor Head Mount Draw 24 Position the pilot holes horizontally on the vertical centre line of the door Fasten the bracket 828 to the door jamb or wall by means of...

Page 14: ...to the door by means of 2 bolts not supplied of the right size and type accor dingly to your door draw 30 Warning the fastening area must be reinforced and structurally resistant 7 step Door fixing Dr...

Page 15: ...en automatically while mooving the door WARNING to control the door with your radio remote control the trolley must be locked 7 Manual release system Once the opener has been installed tighten the bel...

Page 16: ...raw 39 40 Connect the 230 V 50 60 Hz input cable to the transformer terminal board draw 41 42 43 A fuse is mounted on the transformer to protect low voltage system draw 42 We recommand to use a cable...

Page 17: ...red by each electronic board of the gate opener To erase the codes from the control board To deactivate any unwanted remote first erase its memory from the electronic board of your garage opener as fo...

Page 18: ...ax pause time of 100 sec 1 ANTENNA CABLE 2 GROUND Antenna 3 5 START 4 5 Photo beam contact 6 PHOTO BEAM POSITIVE 7 PHOTO BEAM NEGATIVE 7 8 blinking light 24V 10W max 9 10 extra courtesy light 13 14 li...

Page 19: ...nd green will stop the door movement when they get in correspondance of thelli mit switch Red Flag closed door Green Flag open door 1 your door closed Position the red flag in correspondance of the li...

Page 20: ...eries is approx 2 years Batteries can be replaced with the following model 12V type A23 5mA Protection fuse In the event of short circuit the protection fuse can be replaced with the following type Fu...

Page 21: ...of worn out parts b Transport handling or installation costs relating to this product c Improper use mistakes in the operation and incorrect installation d Damages caused by fire water natural phenome...

Page 22: ...d safety norms indicated by the Manufacturer are in conformity to the applicables sections of standards EMC EN61000 6 2 EN61000 6 3 EN301489 3 EMF EN50366 EN50371 SAFETY EN60335 1 4 ed EN60335 1 2002...

Reviews: