![Ducasa AVANT-DGi+ 1000 Operating And Installation Instructions Download Page 12](http://html1.mh-extra.com/html/ducasa/avant-dgi-1000/avant-dgi-1000_operating-and-installation-instructions_2537521012.webp)
12
Firmware Version (C4)
It shows internal software installed in the
electronics.
Open Window detection (C5)
In order to save energy, if a window opens and
causes a sudden drop in temperature the heater
will stop heating. If the heater is heating, it will be
disconnected for 30 minutes and shows the Open
Window icon on the display.
By default this function is deactivated. To change
the status of the function, press the +/- button and
then press ok to confirm.
This function detects a temperature drop of
0.6ºC every minute over a period 4 minutes.
The heater will restore normal function in any of
these situations:
•
After 30 minutes
•
If the temperature increases by 0.2ºC for 1
minute from the point of activation.
•
Pressing any button on the Heater
Eco-Start (C6)
With this feature activated the radiator will
learn what time it should switch on to achieve the
required room temperature at your programmed
time.
The heater will monitor the room temperature
over a rolling 10 day period to establish how
quickly the room reaches temperature and uses
this information to switch the heater on at the
correct time.
By reaching the required temperature at the set
time and not before, energy use and running costs
are reduced.
By default this function is deactivated.
To change the status of the function, press the
+/- button and then press ok to confirm.
If this function is active then
will be shown
on the LCD screen.
This function is only active while in AUTO mode.
If the heater is reset, all previous Eco-Start data
will be deleted.
Radiator Reset
Resetting the radiator will return all settings
to the factory defaults and will also delete any
‘pairing’ with a
Gateway. To
activate the RESET feature press the
OK
button
and the
CONFIG
button for 10 seconds. The
following screen will appear:
To confirm the reset, press
OK
again, to cancel
the
RESET
press any other button.
Factory Defaults
•
Working mode: OFF
•
Comfort Temp : 19ºC
•
Economy Temp : 17ºC
•
Frost Protection Temp : 5ºC
•
Manual Mode Temp: 19ºC
• T
emperature Compensation: 0ºC
•
No RF paired network
•
Temperature units ºC
•
Control type: PID
•
Default Programme: All Economy
•
Open Window detection OFF.
•
Eco-Start OFF.
Summary of Contents for AVANT-DGi+ 1000