Adjust Programmed Temperatures
Adjusting temperature in the following way will
only effect the temperatures used for programmed
modes.
To change these set up
temperatures press the
CONFIG
button and the
following screen appears:
When the temperature setup icon
starts
flashing, press OK to scroll through each mode.
Press the +/- button to change the temperature
of each mode then press
OK
to confirm and go to
the next MODE to exit temperature setup, press
CONFIG.
KEYPAD LOCKING (ANTI-TAMPER)
The Avant DGi+ can be locked to prevent any
unauthorised person (children, people in public
places, nurseries, offices, hotels etc.) altering the
settings of the radiator. To lock the keypad press
and hold the +/- buttons at the same time for 3
seconds until “bloc” appears on the screen. Any
button presses will be ignored and “bloc” will be
displayed on the screen.
To unlock keyboard, once again press and hold
the +/- buttons for 3 seconds until the word ‘bloc’
disappears.
When the Avant DGi+ is locked the radiator
will still receive communications from the
Gateway.
ADVANCED SETTINGS
To enter the advanced settings mode, press
CONFIG
while the radiator is in one of the main
modes (OFF, AUTO, MANUAL). The following
screen will appear:
Now press the
CONFIG
button for 5 seconds
and C1 appears on the screen.
To scroll through the advanced settings (C1 to
C6) use the +/- buttons and choose the required
setting by pressing OK. The advanced settings
are:
C1-> Choose ºF or ºC
C2->Choose type of thermostat accuracy
C3->
T
emperature Compensation
C4-> Firmware version
C5-> Open Window detection
C6-> Eco-Start
Degrees Fahrenheit or Celsius (C1)
Select ºC or ºF with the +/- buttons and confirm
with OK button
Type of Thermostat Accuracy (C2)
This setting shows the type of thermostat
accuracy currently being used. There are 5 types
of accuracy PID, hysteresis of 0.25ºC, hysteresis
of 0.35ºC, hysteresis of 0.50ºC and hysteresis of
0.75ºC.
To change the type of accuracy press +/- button
and confirm your selection by pressing the
OK
button. The screens shown are:
T
emperature Compensation
(C3)
This setting is used to balance two radiators
in the same room or to sync the Avant DGi+
with a thermostat. It will alternate between the
temperature compensation (offset) and the
measured temperature with offset applied. Alter
the offset with the +/- buttons and confirm with OK.
Temperature compensation can be adjusted up
to +/- 3ºC
recognises the system’s time automatically.