AC Parallel Operation
It is possible to connect two
P
2000i to each other, using a parallel cable kit, to increase available power
output.
• Connect PARALLEL OPERATION CABLES to two P2000i generators according to the instructions provided with the
cable kit.
• Make sure the
Economy
switch is in the “OFF” position on both generators.
• All electronic devices should be turned “OFF”
and disconnected from generators prior to starting generator engines.
• Start generator engines. Make sure the green output indicator light comes on for each generator.
• When engines have stabilized, plug in electrical device to AC receptacle and turn on first load.
• Allow generator output to stabilize (engine attached devices run evenly) before plugging in the next load.
Maximum Power in Parallel Operation:
4.0kVA
Rated Power in Parallel Operation:
3.0kVA
Limit operation time to 3 minutes for load requiring
maximum output. For continuous operation, do not exceed
the rated output.
Note:
It is strongly recommended to plug in devices with
the overloading the generator.
Note:
Most electronic devices require power beyond its rated wattage to start. This additional power is referred to as
surge watts and usually lasts between 2-3 seconds. When an electronic device is started, the red overload indicator
may come on. This is normal. If the light stays on disconnect all electronic devices and stop the engine. Refer to “Engine
Overload Indicator Light” on page
8
.
OPERATION
• A faulty appliance or power cord can create electric shock. Do not use electronic devices that have a damaged cord
or plug.
• If an appliance begins to operate abnormally, becomes sluggish, or stalls, turn off and disconnect appliance
immediately. The appliance may have a fault or its rated load capacity exceeds the power supply of the
generator.
Only connect electronic devices to the generator that are in good working order and do not
exceed the rated power supply of the parallel generators or the desired receptacle.
WARNING!
WARNING!
Never connect generators that are different models.
• Only connect this generator to another
P2000
i
Generator.
• Only use a manufacturer approved parallel operation cable kit to connect generators.
• Do not run generators in parallel operation in excess of 30 minutes.
• The parallel cable must be removed if operating only one generator.
• Never disconnect or remove the parallel operation cable while generator is still running.