Dual Pumps BP 125 Operating Instructions Manual Download Page 6

The following are not covered by the guarantee:
•  direct or indirect damage, of any type, caused by falls, incorrect use of the pump 

and failure to observe regulations regarding safety, installation, operation and 
maintenance which are contained in this manual and in the manual for the machine 
which incorporates the pump;

• damage caused by the inactivity of the pump for repairs; 
• any parts which are subject to wear during normal use; 
• any parts which are deemed faulty due to negligence or carelessness during use; 
•  damage caused by the use of non-original spare parts or accessories or not 

expressly authorised by the Manufacturer, and by repairs not completed by a Skilled 
Technician 
The guarantee becomes void should the pump, and especially its safety devices, be 
tampered with and the Manufacturer is no longer liable.

The Manufacturer reserves the right to make any modifi cation at any time which it 
deems necessary to improve the product and is not liable to make these modifications 
to previously manufactured products, be they delivered or under delivery.
The conditions in this section exclude any previous explicit or implicit condition.

1.2 THE ADDRESS OF THE MANUFACTURER

The address of the manufacturer of the pump is given in the “Declaration of the 
Manufacturer” at the front of the instruction manual.

1.3 USE AND CONSERVATION OF THIS OPERATING AND MAINTENANCE
MANUAL

The operating and maintenance manual is an integral part of the pump and must be 
kept in a safe place for future reference so that it may be readily consulted in case of 
need.
The operating and maintenance manual contains important information for the safety of 
the operator and of any people near him and for the protection of the environment.
In case of deterioration or loss, a new copy should be requested from the dealer or 
from an authorised service centre.
If the pump is passed on to a third party, please make sure this operating and 
maintenance manual is also given to the new owner.
We take great care when drawing up our manual. If you note any mistakes, please do 
inform the Manufacturer or an authorised service centre.
The Manufacturer reserves the right to modify, update and correct this manual without 
notice. It is illegal to copy this manual, even partially, without prior authorisation by the 
Manufacturer.

1.4 SYMBOLS

The symbol: 

CAUTION

next to certain parts of the text, is to indicate that there is the firm possibility of injury to 
persons if the relative instructions and indications are not followed.

The symbol: 

WARNING

next to certain parts of the text, is to indicate that there is the possibility of damaging 
the pump if the relative instructions are not followed.

2

!

Summary of Contents for BP 125

Page 1: ...Operating Instructions 793 1300 pumps Diaphragm Pump Unit...

Page 2: ......

Page 3: ...ve all the basic information to operate the pump set safely and effectively It is recommended the manual and it s accompanying leterature be read and understood before attempting to operate the equipm...

Page 4: ...ual 2 1 4 Symbols 2 2 Features And Technical Specifications 3 2 1 Identification Of Components 3 2 1 Identification Of Components continued 4 2 2 Safety Devices 5 2 3 Identification Label 5 3 Designat...

Page 5: ...the Manufacturer use of non original or non specific spare parts for this model of pump repairs which were not completed by a Skilled Technician 1 1 TERMS OF THE GUARANTEE The guarantee is valid for...

Page 6: ...n the Declaration of the Manufacturer at the front of the instruction manual 1 3 USE AND CONSERVATION OF THIS OPERATING AND MAINTENANCE MANUAL The operating and maintenance manual is an integral part...

Page 7: ...SPEED OF ROTATION Water flow at maximum pressure l min US gpm Water flow at 0 bar l min US gpm Maximum pressure bar psi Sound level dB A 117 30 9 121 32 0 20 290 70 WEIGHT kg lb 13 0 28 6 All feature...

Page 8: ...eed Pressure Feed Isolator Tap Safety Valve Discharge Hose Pump Oil Level Filler Gearbox Breather Oil Filler Pressure Off Lever By Pass to Tank Pressure Gauge Pressure Adjustment Pressure Regulating V...

Page 9: ...rom coming into contact with the moving parts of the pump shaft c Pressure limit adjustment valve This is standard for certain versions and is available as an optional accessory for others This valve...

Page 10: ...t be those endorsed by the Manufacturer The pump is not suitable for use in certain situations such as in corrosive or explosive atmospheres Contact the Manufacturer s service centre before use on boa...

Page 11: ...age the delivery pipe and the sprinkler lance During operation never leave the pump unattended and make sure it is out of reach of children and animals Pay particular attention when using it in kinder...

Page 12: ...se check that the oil level either corresponds to the reference notch on the volumetric compensator 2 1 3 or is visible from the level cap Remember that the level of the oil must always be checked whe...

Page 13: ...rops in excess of this The pump must be provided with an adequate intake filter In case of doubt contact a Skilled Technician Check that the filter is perfectly clean at all times The internal diamete...

Page 14: ...of its operation and to top up the liquid if necessary as instructed in the PRELIMINARY PROCEDURES section 6 SWITCHING OFF AND STORAGE 6 1 SWITCHING OFF CAUTION Complete any operations required to swi...

Page 15: ...water in the oil excessive consumption of oil sudden lack of oil in the volumetric compensator WARNING To avoid the negative consequences of this malfunction stop operation of the pump immediately and...

Page 16: ...OFF section If it is not possible to restore correct operation of the pump using the information in the table below contact a Skilled Technician INTERVAL FOR MAINTENANCE ACTION Every 300 hours Check...

Page 17: ...13 10 Warranty Limited Warranty Supplied by Dual Pumps Ltd For warranty terms refer to Section 7 of our Terms and Conditions at www dualpumps co uk company legal or scan the QR code...

Page 18: ...14 FIG 3 FIG 8...

Page 19: ...15...

Page 20: ...Unit 8 Hudson Road Saxby Road Ind Est Melton Mowbray Leicestershire LE13 1BS Telephone 44 0 1664 567226 Fax 44 0 1664 410127 E mail info dualpumps co uk www dualpumps co uk pumps DP PTUH V1 01 03 20...

Reviews: