5. OPERATION

 CAUTION

•  The pump must not be put into operation if the machine in which it is incorporated 

does not comply with the safety requirements defined by European Directives. Their 

compliance is guaranteed if the CE mark is present together with the manufacturer’s 

Declaration of Conformity for the machine that incorporates the pump.

•  Before starting to use the pump, read both this manual and the manual for the machine that 

incorporates the pump carefully. It is important to be sure that you have fully understood 
how both the pump and the machine that incorporates the pump work concerning the 
interception of the liquids.

•  The pump must be used with care and attention. It is your responsibility to make sure that 

any infrequent users have read this manual and are acquainted with the operation of the 
pump; otherwise do not allow others to use the pump. Pumps must not be used by children 
or by unauthorised personnel.

•  Comply with the safety warnings in the operating and maintenance manual of the machine 

that incorporates the pump especially as regards the use of personal protection (protective 
glasses, headphones, facemasks etc).

•  Do not use the pump if: 

- the pump has been bumped 
- there are obvious leaks of oil. 
- there are obvious leaks of water.

In these circumstances, the pump should be tested by a Skilled Technician.
•  It is especially important to pay great attention when the pump is used in areas where there 

are moving vehicles as these can crush or damage the delivery pipe and the sprinkler lance.

•  During operation, never leave the pump unattended and make sure it is out of reach of 

children and animals. Pay particular attention when using it in kindergartens, nursing homes 
and old people’s homes, as unsupervised children, elderly people and disabled people may 
be present in such places.

•  Before starting to use the pump, put on clothing which guarantees adequate protection 

against the possibility of incorrect manoeuvres of the jet of pressurised water. Do not 
operate the pump near people unless they are also wearing protective clothing.

•  High-pressure jets of water can be dangerous if they are not used properly. Do not point the 

jet in the direction of people, animals, and energized electrical appliances or towards the 
machine which incorporates the pump.

•  Hold the sprinkler lance fi rmly during use: when operating its control lever, the operator is 

subjected to the backlash of the high pressure.

•  Do not point the jet towards oneself or other people in order to clean off clothing or 

footwear.

•  Do not point the high-pressure jet towards materials, which contain asbestos or other 

harmful substances.

•  Make sure that the pump’s moving parts are adequately protected and that they are not 

accessible to unauthorised personnel.

•  Do not come within reach of the pump’s moving parts, even if they are adequately protected.
• Do not remove the protective devices of the pump’s moving parts.
• Do not carry out any maintenance on the pump if it is in use.
• Follow the instructions in the “Designated Uses” section.
•  Do not modify the conditions of the installation of the pump, especially its attachment and its 

hydraulic connections.

7

!

Summary of Contents for BP 125

Page 1: ...Operating Instructions 793 1300 pumps Diaphragm Pump Unit...

Page 2: ......

Page 3: ...ve all the basic information to operate the pump set safely and effectively It is recommended the manual and it s accompanying leterature be read and understood before attempting to operate the equipm...

Page 4: ...ual 2 1 4 Symbols 2 2 Features And Technical Specifications 3 2 1 Identification Of Components 3 2 1 Identification Of Components continued 4 2 2 Safety Devices 5 2 3 Identification Label 5 3 Designat...

Page 5: ...the Manufacturer use of non original or non specific spare parts for this model of pump repairs which were not completed by a Skilled Technician 1 1 TERMS OF THE GUARANTEE The guarantee is valid for...

Page 6: ...n the Declaration of the Manufacturer at the front of the instruction manual 1 3 USE AND CONSERVATION OF THIS OPERATING AND MAINTENANCE MANUAL The operating and maintenance manual is an integral part...

Page 7: ...SPEED OF ROTATION Water flow at maximum pressure l min US gpm Water flow at 0 bar l min US gpm Maximum pressure bar psi Sound level dB A 117 30 9 121 32 0 20 290 70 WEIGHT kg lb 13 0 28 6 All feature...

Page 8: ...eed Pressure Feed Isolator Tap Safety Valve Discharge Hose Pump Oil Level Filler Gearbox Breather Oil Filler Pressure Off Lever By Pass to Tank Pressure Gauge Pressure Adjustment Pressure Regulating V...

Page 9: ...rom coming into contact with the moving parts of the pump shaft c Pressure limit adjustment valve This is standard for certain versions and is available as an optional accessory for others This valve...

Page 10: ...t be those endorsed by the Manufacturer The pump is not suitable for use in certain situations such as in corrosive or explosive atmospheres Contact the Manufacturer s service centre before use on boa...

Page 11: ...age the delivery pipe and the sprinkler lance During operation never leave the pump unattended and make sure it is out of reach of children and animals Pay particular attention when using it in kinder...

Page 12: ...se check that the oil level either corresponds to the reference notch on the volumetric compensator 2 1 3 or is visible from the level cap Remember that the level of the oil must always be checked whe...

Page 13: ...rops in excess of this The pump must be provided with an adequate intake filter In case of doubt contact a Skilled Technician Check that the filter is perfectly clean at all times The internal diamete...

Page 14: ...of its operation and to top up the liquid if necessary as instructed in the PRELIMINARY PROCEDURES section 6 SWITCHING OFF AND STORAGE 6 1 SWITCHING OFF CAUTION Complete any operations required to swi...

Page 15: ...water in the oil excessive consumption of oil sudden lack of oil in the volumetric compensator WARNING To avoid the negative consequences of this malfunction stop operation of the pump immediately and...

Page 16: ...OFF section If it is not possible to restore correct operation of the pump using the information in the table below contact a Skilled Technician INTERVAL FOR MAINTENANCE ACTION Every 300 hours Check...