5.2 PIPE CONNECTIONS
CAUTION
• Do not connect up to the mains supply of drinking water.
• All pipes must be securely fi xed to the relative coupling with grips.
Refer to
FIG 3. PAGE 15
for the intake, delivery and bypass connections: this depicts the
general layout of a hypothetical machine incorporating the pump. Also refer to the following
table:
a) For use with a sprinkler lance:
- Fully unroll the high-pressure pipe.
- Use the appropriate grip to connect the high-pressure pipe to a tap on the pump or on
the control unit.
- Make sure the lever on the lance is closed and then connect the lance to the high
pressure pipe.
b) Connect the intake pipe to the relative coupling if the Manufacturer of the machine
incorporating the pump has not already done so. Check the filter is clean.
WARNING
• The intake of the pump must use a tank at atmospheric pressure and the level of the liquid
must be between 1m / 3.3ft above and 1 m /3.3 ft below the intake coupling (see fi g. 8);
never connect the pipe to pressurized water pipes.
• For periods of 10÷15 min, the intake of the pump can operate at drops of up to 3m/ 9.8 ft:
it must not operate at drops in excess of this.
• The pump must be provided with an adequate intake filter. In case of doubt, contact a
Skilled Technician. Check that the filter is perfectly clean at all times.
• The internal diameter of the intake and bypass pipes must be equal to the external
diameter of the intake and bypass couplings respectively. They must have a nominal
pressure of 10 bar /145 psi
• The internal diameter of the delivery pipes must be equal to the external diameter of the
delivery couplings. Their nominal pressure must not be below the maximum pressure of
the pump.
• Do not supply the pump with water at a temperature in excess of 40°C/104°F or below
5°C/ 41°F.
• Do not operate the pump for a long time if it is not connected to a water supply.
• Do not supply the pump with salt water or water containing impurities. In this event, run the
pump for a few minutes with clean water.
5.3 START UP
CAUTION
• Complete any operations required to start up the machine that incorporates the pump as
recommended by its manufacturer.
• Read the instructions and warnings on the label of chemicals to be distributed by the
pump to take the appropriate steps in order to avoid danger for the operator or for the
environment.
1
Tank
2
Intake filter
3
Intake circuit
4
Pump
5
Delivery circuit
6
By pass circuit
7
Sprinkler lance (typical application)
9
!
!
Summary of Contents for BP 125
Page 1: ...Operating Instructions 793 1300 pumps Diaphragm Pump Unit...
Page 2: ......
Page 18: ...14 FIG 3 FIG 8...
Page 19: ...15...