Dual Pumps BP 125 Operating Instructions Manual Download Page 5

1. GENERAL INFORMATION

Congratulations for choosing one of our products! We would like to remind you that 
we took the safety of the operator, the efficiency of its use and the protection of the 
environment into great consideration when designing and manufacturing this product.

In order to preserve its features over time, please read and follow this manual carefully.

Particular attention must be awarded to the parts with the following symbol:

CAUTION

as they contain important instructions regarding safety when using the pump.

The Manufacturer is not liable for damage caused by:
•  failure to comply with these instructions and the instructions for the machine which 

incorporates the pump;

• use of the pump not included in the list in the “DESIGNATED USE” section; 
•  failure to comply with current safety regulations and regulations for the prevention of 

accidents in the workplace when using the pump;

• incorrect installation 
• failure to carry out the anticipated maintenance; 
• modifications or actions without prior authorisation by the Manufacturer; 
• use of non-original or non-specific spare parts for this model of pump; 
• repairs which were not completed by a Skilled Technician.

1.1 TERMS OF THE GUARANTEE

The guarantee is valid for a period of 12 months from the date on the sales document 
(receipt, invoice etc.)

The purchaser has sole right to the replacement of the parts which the Manufacturer, 
or his authorised representative, deems faulty as regards their material or manufacture. 
This does not imply any right to compensation for any type of direct or indirect damage. 
Any costs for labour, packing and transportation are at the purchaser’s expense.

Should the product be sent to the Manufacturer for repairs under this guarantee, it 
must be complete with all its original parts and not be tampered with upon arrival. Any 
request under this guarantee will be denied if this is not the case. All replaced parts 
become the exclusive property of the Manufacturer.

Any faults or failures which occur during or after the period of the guarantee do not 
imply the right to suspend payment or to any further extension.

This guarantee does not cover the replacement of the pump and automatically 
becomes void should the agreed terms of payment not be abided by.

1

!

Summary of Contents for BP 125

Page 1: ...Operating Instructions 793 1300 pumps Diaphragm Pump Unit...

Page 2: ......

Page 3: ...ve all the basic information to operate the pump set safely and effectively It is recommended the manual and it s accompanying leterature be read and understood before attempting to operate the equipm...

Page 4: ...ual 2 1 4 Symbols 2 2 Features And Technical Specifications 3 2 1 Identification Of Components 3 2 1 Identification Of Components continued 4 2 2 Safety Devices 5 2 3 Identification Label 5 3 Designat...

Page 5: ...the Manufacturer use of non original or non specific spare parts for this model of pump repairs which were not completed by a Skilled Technician 1 1 TERMS OF THE GUARANTEE The guarantee is valid for...

Page 6: ...n the Declaration of the Manufacturer at the front of the instruction manual 1 3 USE AND CONSERVATION OF THIS OPERATING AND MAINTENANCE MANUAL The operating and maintenance manual is an integral part...

Page 7: ...SPEED OF ROTATION Water flow at maximum pressure l min US gpm Water flow at 0 bar l min US gpm Maximum pressure bar psi Sound level dB A 117 30 9 121 32 0 20 290 70 WEIGHT kg lb 13 0 28 6 All feature...

Page 8: ...eed Pressure Feed Isolator Tap Safety Valve Discharge Hose Pump Oil Level Filler Gearbox Breather Oil Filler Pressure Off Lever By Pass to Tank Pressure Gauge Pressure Adjustment Pressure Regulating V...

Page 9: ...rom coming into contact with the moving parts of the pump shaft c Pressure limit adjustment valve This is standard for certain versions and is available as an optional accessory for others This valve...

Page 10: ...t be those endorsed by the Manufacturer The pump is not suitable for use in certain situations such as in corrosive or explosive atmospheres Contact the Manufacturer s service centre before use on boa...

Page 11: ...age the delivery pipe and the sprinkler lance During operation never leave the pump unattended and make sure it is out of reach of children and animals Pay particular attention when using it in kinder...

Page 12: ...se check that the oil level either corresponds to the reference notch on the volumetric compensator 2 1 3 or is visible from the level cap Remember that the level of the oil must always be checked whe...

Page 13: ...rops in excess of this The pump must be provided with an adequate intake filter In case of doubt contact a Skilled Technician Check that the filter is perfectly clean at all times The internal diamete...

Page 14: ...of its operation and to top up the liquid if necessary as instructed in the PRELIMINARY PROCEDURES section 6 SWITCHING OFF AND STORAGE 6 1 SWITCHING OFF CAUTION Complete any operations required to swi...

Page 15: ...water in the oil excessive consumption of oil sudden lack of oil in the volumetric compensator WARNING To avoid the negative consequences of this malfunction stop operation of the pump immediately and...

Page 16: ...OFF section If it is not possible to restore correct operation of the pump using the information in the table below contact a Skilled Technician INTERVAL FOR MAINTENANCE ACTION Every 300 hours Check...

Page 17: ...13 10 Warranty Limited Warranty Supplied by Dual Pumps Ltd For warranty terms refer to Section 7 of our Terms and Conditions at www dualpumps co uk company legal or scan the QR code...

Page 18: ...14 FIG 3 FIG 8...

Page 19: ...15...

Page 20: ...Unit 8 Hudson Road Saxby Road Ind Est Melton Mowbray Leicestershire LE13 1BS Telephone 44 0 1664 567226 Fax 44 0 1664 410127 E mail info dualpumps co uk www dualpumps co uk pumps DP PTUH V1 01 03 20...