Install RO Drain Connector
Drain Connector Installation
Choose the drain outlet location. See Fig. 1 (page 3)
NOTE: Extra care should be taken when entering drains near dishwashers or food waste disposals, as backflow may occur
through the air gap and cause flooding.
1
Remove protective cover from back of Foam Seal
N.
Knock out center hole and align holes then attach to Drain Connector
front plate
K.
2
Position the Drain Connector
K
on the sink drain pipe above the drain trap. Allow room for drilling. Tighten Screws
L
and
Nuts
M
securely.
3
Use a battery powered or properly grounded drill. Using the Drain Connector
K
port as a drill guide, drill a 7/32” hole through
the wall of the drain pipe. Do NOT penetrate the opposite side of the pipe and be careful not to damage the side of the drain
port fitting.
4
If you wish to install your drain in a remote location refer to page 11.
STEP 3
Install RO Filter System Assembly
The Reverse Osmosis Filter System Assembly Head
A
is mounted on Mounting Screws
C.
The Mounting Screws
C
allow you to lift the RO Filter System Assembly without any hardware removal.
1
Choose an easy-to-access area under the sink to mount the RO Filter System Head
A.
NOTE: To allow adequate space for filter changes, allow a minimum clearance of 4” - 6” below the filter to the floor. The
Filter System Assembly must be mounted in a vertical position.
NOTE: Mount the Filter System Head to a solid cabinet wall or wall. If a solid surface is not available, use hollow-wall
anchor bolts or toggle bolts (not included) to secure to the wall.
2
Using the Built-in Bracket on the back of the RO System Head
A
, mark the holes for the Mounting Screws
C
, on the wall surface.
3
Using a 1/8” drill bit, drill two pilot holes for the Mounting Screws
C.
Insert Mounting Screws
C
into the wall with a Phillips
screwdriver, leaving approximately 3/8” of each Mounting Screw
C
exposed.
4
Hang the RO System Head
A
on the Mounting Screws
C.
Be sure that all electrical appliances and outlets are turned off at the
circuit breaker before working in cabinet area.
Please wear safety glasses to protect
eyes when drilling.
CAUTION
WARNING
2
M
N
K
L
L
3
10 1/2” minimum up from floor. This distance allows
for space to change filters.
A
C
C