WFRO60X-1
V4.5E
13
QuickTwist
®
Filter Replacement
1
Turn off the cold water shut-off valve to the RO Filter System Assembly.
2
Turn each QuickTwist
®
Filter
B1, B2, B3
from right to left until it releases. Gently pull down on each used QuickTwist
®
Filter to
remove it from the RO System Head
A.
Discard the used QuickTwist
®
Filters.
NOTE: Place a pan or bucket under the RO Filter System to catch any water drips.
3
Hold each new QuickTwist
®
Filter with the label facing to the left slightly. The two nozzles on top of each QuickTwist
®
Filter should be toward the back of the QuickTwist
®
Filter. If holding properly, the two extended flanges on top of the QuickTwist
®
Filter should be out to each side.
NOTE: When viewing the QuickTwist® RO System from the front, the B1 and B3 are both WFQTC30001 filters. These filters
must be positioned on either side of the center position while the B2 is the WFROM1000X or Membrane and must be positioned
in the center position.
4
Lift each QuickTwist
®
Filter straight up into the RO System Head
A
until the two nozzles seat into the ports and the two extended
flanges on top of the QuickTwist
®
Filter are fully engaged into the RO System Head
A.
5
Turn each QuickTwist
®
Filter from the left to right until it stops.
6
Turn on the cold water shut-off valve and the RO Faucet and check for any leaks. If there are leaks, refer to the troubleshooting
information on page 16 of the installation instructions.
7
Pressure Test and purge system per Step 8.