2- IMPORTANT SAFETY INFORMATION 

2.1 Fire prevention:

 The use of any other alternative lamp is not recommended and will null and void the fixture's warranty.
-Never locate the fixture on any flammable surface.
-Minimum distance from flammable materials: 1 MT.
-Minimum distance from the closest illuminable surface: 2 MT.
-Replace any blown or damaged fuses only with fuses of identical value. Refer to the wiring diagram if 
there is any doubt.
-Connect the projector to mains power via a thermal magnetic circuit breaker.

2.2 Prevention of electric shock:

-High voltage is present inside the unit. Unplug the unit  prior to performing any function which involves 
touching the inside of the moving head, including lamp replacement.
-The level of technology present in the Xr5 requires the assistance of specialised personnel for all 
servicing. Please refer to an authorised DTS service centre.
-A good earth connection is essential for proper functioning of the projector.
-Never connect the unit without proper earth connection.
-The fixture should  be located in places with a good air ventilation.

2.3 Protection against ultraviolet radiation:

-Never turn on the lamp if any of the lenses, filters or ABS covering is damaged. Their respective 
shielding functions will only operate efficiently if they are in perfect working order.
-Never look directly  the lamp when it is on.

2.4 Safety:

-The projector should always be installed with bolts, clamps and other tools that are capable of 
supporting the weight of the unit.
-Always use a second safety cable to sustain the weight of the unit in case of the failure of the main 
fixing point.
-The external surface of the unit, at various points, may exceed 70°C. Never handle the unit until at 
least 10 minutes have elapsed since the lamp was turned off.
-Always replace the lamp if any physical damage is evident.
-Never install the fixture in an enclosed area lacking sufficient air flow. The ambient temperature should 
not exceed 40°C.
-A hot lamp may explode, so always wait for at least 10 minutes prior to attempting to replace the lamp.
-Always wear suitable hand protection when handling the lamp.

2.5 Level of protection against the penetration of solid and liquid matter:

-The projector is classified as an ordinary appliance and its protection level against the penetration of 
solid and liquid matter is IP 20.

 XR5 can fit a Philips MSD250/2 or a Osram HSD250/2 or a GE CSD250/2.  

ARC 1200

XR 5  WASH

Summary of Contents for XR 5 WASH

Page 1: ...XR 5 WASH XR 5 WASH GB User Manual Rel 1 1...

Page 2: ...or circuits described herein Les informations contenues dans le pr sent manuel ont t r dig es et contr l es avec le plus grand soin Nous d clinons toutefois toute responsabilit en cas d ventuelles ine...

Page 3: ...TION 7 5 1 Safety cable 5 2 Protection against liquids 5 3 Movement 5 4 Risk of fire 5 5 Forced ventilation 5 6 Ambient temperature 6 MAINS CONNECTION 8 6 1 Protection 7 DMX SIGNAL CONNECTION 9 7 1 DM...

Page 4: ...and 5 600 K CMY colour generation a colour wheel 6 dichroic filters open with linear selection and electronic or electromagnetic ballast Optical group Fresnel lens 150 mm Borosilicate dichroic parabo...

Page 5: ...aviolet radiation Never turn on the lamp if any of the lenses filters or ABS covering is damaged Their respective shielding functions will only operate efficiently if they are in perfect working order...

Page 6: ...DO NOT USE UNDUE FORCE ON THE GLASS In case of difficulty read again the instructions and repeat the procedure 3 Replace the lamp assembly and tighten the screws X Y Z which were previously removed p...

Page 7: ...is moving Four quarter turn fast locks placed on the base of the units allows by using the two fast lock C clamps provided in the box to fix the unit in any position 5 1 Safety cable We recommend the...

Page 8: ...hould never be installed in places that lack a constant air flow The ambient temperature should NOT exceed 40 C 6 MAINS CONNECTION XR5 with electromagnetic ballast operate at 230 VOLT 50 60 Hz Prior t...

Page 9: ...as occurred DMX signal not present DMX address not valid DMX reception problem For Installations where long distance DMX cable connections are needed we suggest to use a DMX terminator The DMX termina...

Page 10: ...ss 1 Press the UP DOWN key until you reach the required DMX channel The numbers on the display will start to flash but the new DMX address hasn t yet been set 2 Press ENTER to confirm your selection T...

Page 11: ...t and vice versa Up Down Counterclockwise Clockwise Up Down MENU ENTER Up Down TILT MOVEMENT INVERSION To reverse Tilt movement from bottom upwards and vice versa Up Down Counterclockwise Clockwise Up...

Page 12: ...DEFAULT 12 MENU ENTER Up Down ENTER ENTER Up Down DEFAULT 4 SPEED control Pan Tilt Speed control 8 DISPLAY FUNCTIONS PAN TILT DIMMER SHUTTER MAGENTA COLOR CYAN YELLOW EFFECTS ZOOM ENTER MENU Up Down...

Page 13: ...FREE REMOVE POWER TO TILT MOTOR MENU ENTER TIMER lamp life TIME reset possible and total UNIT LIFE TIME reset not possible Up Down ENTER Up Down ENTER Up Down ENTER Up Down ENTER 13 8 DISPLAY FUNCTION...

Page 14: ...ects the position Fan speed regulation makes it possible to reduce fan noise However the ambient temperature must be less than 35 C 11 ERROR MESSAGES 14 ERROR ENCODER PAN ERROR ENCODER TILT ERROR DMX...

Page 15: ...ENTER Up Down ENTER Up Down ES ENTER Up Down ENTER Up Down ES ENTER Up Down ENTER Up Down ES ENTER Up Down ENTER Up Down ES ENTER Up Down ENTER Up Down ES ENTER Up Down ENTER ES ENTER Up Down ENTER E...

Page 16: ...this type of maintenance are a brush and a common vacuum cleaner or an air compressor If necessary clean the fans and air passages more frequently 15 PERIODIC CONTROLS Lamp The lamp should be replaced...

Page 17: ...319 DMX CHANNEL 4 Parameter TILT lsb DMX CHANNEL 5 Parameter MOVEMENT SPEED DMX range Value Mid point DMX value Move range degrees Mode Option Function 0 10 Standard 11 25 Fast movement 26 127 Vector...

Page 18: ...205 Flash closed speed 3 206 219 Flash closed speed 4 max 220 227 Colours Macros in black out 228 233 Pan Tilt in black out 234 255 Open DMX CHANNEL 8 Parameter COLOUR DMX range Value Mid point DMX va...

Page 19: ...55 Left rotation speed 9 max DMX CHANNEL 9 Parameter CYAN DMX range Value Mid point DMX value Move range degrees Mode Option Function 0 255 Proportional colour DMX CHANNEL 10 Parameter MAGENTA DMX ran...

Page 20: ...ro 10 Macro 11 Macro 12 Macro Macro Macro Macro Macro Macro Macro Macro Macro Macro 13 Macro 14 Macro 15 Macro 16 Macro 17 Macro 18 Macro 19 Macro 20 Macro Macros rainbow wait Macros rainbow wait Macr...

Page 21: ...s Mode Option Function 0 29 No effect 30 85 Lamp OFF active after 3 seconds 86 170 Internal motor Reset 171 235 Total Reset 236 255 Lamp ON active after 3 seconds DMX CHANNEL 16 Parameter LAMP RESET D...

Page 22: ...C041 D01 DARK BLUE SW490 COL6 COL5 COL4 COL3 COL2 COL7 COL8 0507C047 D01 RED LW 640 22 17 COLOUR WHEEL 1 2 3 4 5 6 7 8 0507K003 CONV FILTER CTB DL542 0507K004 CONV FILTER CTO TC3256 0507C046 D01 WOOD...

Page 23: ...23 ARC 1200 XR 5 WASH NOTE...

Page 24: ...rior written consent from D T S D T S reserves the right to make any aesthetic functional or design modifications to any of its products without prior notice D T S assumes no responsibility for the us...

Reviews: