28
MAIN MENU
LEVEL 1
LEVEL 2
LEVEL 3
FUNCTION
FAN
STANDARD
Fans standard speed
(Default).
If temperature <15°C:
fans OFF.
If temperature >15°C:
fans speed is
increased within the
factory values range.
SILENT
Reduced fans speed
for a low noise
operation.
If temperature <15°C:
fans OFF.
If temperature >15°C:
fans speed is
increased within the
factory values range.
ULTRA SILENT
Low fans speed for a
very low noise
operation.
If temperature <15°C:
fans OFF.
If temperature >15°C:
fans speed is
increased within the
factory values range.
AUTO
Automatic fans speed.
If temperature <40°C:
fans OFF.
If temperature >40°C:
fans speed is
increased related to
system working
conditions.
DEFAULT SET
SURE
To restore factory
settings.
SYSTEM INFO
TEMPERATURE
DRV1 41.4 40.8
DRV2 40.5 41.0
LED 48.2
PSU 43.4
MICRO 1 46.6
MICRO 2 45.5
DRV-1: LED Driver
Master board temperature
monitoring.
DRV-2: LED Driver Slave
board temperature
monitoring.
LED: LED temperature
monitoring.
PSU: Power supply
temperature monitoring.
MICRO 1: Micro controller
of LED Driver Master
board temperature
monitoring.
MICRO 2: Micro controller
of LED Driver Slave board
temperature monitoring.
SOFTWARE
MASTER
DRV1 V.1.00
SLAVE
DRV2 V.1.00
LED Driver Master and
Slave board firmware
release.
TIME COUNTERS
S1 (R G B W)
S2 (R G B W)
S3 (R G B W)
S4 (R G B W)
UNIT LIFE
RGBW LEDs life time
for each sector and
unit life time.
LEDS STATUS
S1 (R G B W)
S2 (R G B W)
S3 (R G B W)
S4 (R G B W)
RGBW LEDs status
monitoring for each
sector:
NA = Not available.
OK = LEDs properly
working.
SH = LEDs in short
circuit.
OP = LEDs in open
circuit.
Summary of Contents for X-BRICK
Page 1: ...X BRICK USER S MANUAL rel 1 0 GB ...
Page 35: ...35 20 LED PIXEL INVERT FUNCTION REFERENCES ...
Page 58: ...58 NOTES ...
Page 59: ...59 NOTES ...