8. Setting the opening and closing time
The factory set opening / closing time is 60 seconds. It is recommended to set the time slightly longer than
needed to open or close the blind, which will ensure complete opening or closing in all conditions. The
maximum adjustable opening and closing time is 255 seconds.
Opening time
To set the shutter opening time other than the factory one:
put the blind in the fully closed position
hold downC1, releaseC1 when theOPEN diode starts blinking
then hold down the remote control button assigned to theOPEN function.After fully opening the blind,
with the required time added, release the remote control button.The opening time will be saved.
Closing time
To set the closing time of the blind other than the factory one:
set the blind in the fully open position
hold down theC2 button, release theC2 when theCLOSE LED
fl
ashes
then hold down the remote control button assigned to theCLOSE function.After closing the blind
completely, with the required time added, release the button.The closing time will be saved.
9. Setting the momentary / continuous mode.
The controller can work in one of two modes:
momentary mode
opening and closing is carried out as long as the control input remains active (manual control button or
remote control button is pressed).
continuous mode
opening and closing is carried out after the controller receives the control signal (pressing the manual
control button or the remote control button).
STEP BY STEP control is always carried out in a continuous mode, regardless of the set mode of
the controller.