6. EasyRX dedicated radio receiver

CAUTION!

EasyRX radio card is intended exclusively for the cooperation with EASY B231- DTM6 control unit produced 
by DTM System. It should not be used autonomously.

6.1. General information
 

This receiver expands functional possibilities of EASY control unit to remote steering with DTM 433MHz 

series remote controls.   

6.2. Receiver card installation

 

It is the best to start the installation of the receiver from connecting the aerial to it. Next, receiver in the 

form of the card - board with the edge connector should be pressed into the socket with the RADIO description on 
a control unit board on the right-hand side (4 pins), side where  buttons are placed towards the connector.

6.3. Subscribing remote controls to the receiver

 

The receiver has three identically programmed channels A, B and C. They are functional equivalents of 

OPEN A, OPEN B and OPEN C inputs in the control unit). In case of the second and third channel we act the same 
as during the programming of the remote control in the first channel (using the button of the second and third 
channel respectively). In order to programme any button of the remote control in the first channel it is necessary 
to:

- press and hold first channel A button
- when first channel A button is pressed, press 
chosen button of the remote control
- first channel A diode flickers which indicates 
success of the operation
- release the button

6.4. Terminals for aerial connection

 

In  the  brand  new  receiver  an  inside 

aerial  170  mm  long  is  connected  to  the 
terminal. To  increase  the  range  of  the  radio 
remote  control,  it  is  necessary  to  connect 
outside stubby aerial. To connect the coaxial 
cable of the outside aerial to the terminal (centre vein of the cable) and to the terminal (cable screen). In order to 
achieve the optimum radio reach it is important to remember about:
- negative influence of the receiver with energetic devices and metal objects in the aerial neighbourhood,
- negative influence of radio interference from other sources,
- negative influence of high-density housing, wet or reinforced concrete walls.
- shorten range with used remote control battery
- increasing range with increasing height of receiver aerial location

6.5. Remote subscribing of new remote control

 

The radio EasyRX card has a program enabling simple subscribing of the new remote control for the user 

without the need for the access to buttons. 
This function is only useful when you have a 
remote  control  already  subscribed  in  the 
memory. To subscribe new remote control in 
this way it is necessary to proceed according 
to fig. 6.

CAUTION!

Possibility of adding remote control 

without the access to the control unit 

dramatically decreases the level of 

security against third parties. 

Fig. 6. 

Remote subscribing of new remote control.

HOLD ANY OF „NEW” 

REMOTE BUTTON 

FOR 15s

HOLD ANY OF 

ALREADY ASSIGNED 

REMOTE BUTTON FOR 

15s

MAX BREAK 

PERIOD 3s

1

1

2

TIME

Fig. 5. 

Subscribing remote control OPEN A to the receiver.

1

1

2

CZAS

2

PUSH NEW

REMOTE

BUTTON

PRESS AND

HOLD

A BUTTON

+

TIME

REMOTES MUST BE IN RADIO RANGE 

Summary of Contents for EASY B232

Page 1: ...S GATE CONTROL UNIT installation and manual version 2 7 EASY B232 DTM System spółka z ograniczoną odpowiedzialnością spółka komandytowa ul Brzeska 7 85 145 Bydgoszcz tel fax 52 340 15 83 340 15 84 www dtm pl dtm dtm pl ...

Page 2: ......

Page 3: ...maximum power in built condenser quantity 230VAC 2 x 350W none 2 Signal lamp output transmitted max 230VAC 6A and OC max 24VDC 6W Periphery power output photocells bolt etc 24V DC 0 5A Photocells transmitter power supply output OC type see function PHOTO TEST Gate bolt output 12V DC engaged for 8 sec on the start of opening Additional output relay potential free max 1A 30V AC DC operating in bista...

Page 4: ...connection Outputs digital steering output Memory capacity 35 remote controls every with individual number in memory Remote control configuration possibility to subscribe any of three functions OPEN A OPEN B OPEN C to any remote control button Possibility to delete all memory yes Possibility to delete single remote control yes Possibility to subjoin remote control without the necessity to access c...

Page 5: ...ptor and execution circuit made on special relays and couplings to connect power of servomotor and protecting steering and signalling elements Moreover it is equipped with the microprocessor control unit with the interface on LED diodes DIP SWITCHes MICROSWITCH button and rotational potentiometers The casing of the control unit has IP 55 level of tightness Impairments placed in the lower part of t...

Page 6: ... MOTOR2 PE OPEN COM CLOSE Servomotor which opens as first important when the leaves open lap should be connected to MOTOR1terminals SecondservomotorshouldbeconnectedtoMOTOR2terminals Enginecondensers proper for this type of servomotor should be connected betweenOPEN andCLOSE terminals of the servomotors The servomotor opening wire should be connected toOPEN terminal closing wire toCLOSE terminal c...

Page 7: ...d should absolutely be programmed in order to adapt its operating parameters to the current installation in particular it is necessary always to set the power of the servomotor always to programme opening and closing times All the envisaged connections should scrupulously followed In the uncertain situation it is forbidden to try out only to read relevant detailed technical cards of installed devi...

Page 8: ... type to theOPENC terminal This button will activate additional channel outputOUTC All unused inputs of NO type should be left not connected Activating the button of the manual steering consists in its momentary pressing OPENA B and C inputs are functional equivalent of radio receiver channels channelA B andC 3 3 10 EasyRXradioreceiverconnector This connector enables the control of servomotor with...

Page 9: ...he servomotor is a result of switching the directionasaresultofdisturbingthephotocell OVER PUSHING start of the servomotor with the maximum powerturnedon ON orturnedoff OFF PRE FLASHING preliminary five second signalling of the lampbeforethemoveofthegateturnedon ON orturnedoff OFF BLINKING LAMP controlling with lamp without the contact breakerbuiltin ON orwithlampwithitsowncontactbreaker OFF Thela...

Page 10: ...ons as well as tothevitalityofmechanicalfittings 5 4 PrzełącznikDIP SWITCHsekcjaMODE tryb logika pracysterownikaEASYB232 DIP SWITCHMODEsection EASYB232controlunitoperationmode logic BelowthereareoperationmodesofEASYcontrolunit Itisnecessarytoanalysetheuserneedsandnext chooseappropriateamongavailable 5 4 1 1 Amode Automatic mode it has function of auto closing the gate after the set time maximum 12...

Page 11: ... rewers blocks OPEN A B PHOTO CL rewers PHOTO OP CL blocks OPEN A B blocks OPEN A B otwiera bramę i zamyka po czasie autozamykania otwiera furtkę i zamyka po czasie autozamykania closes the gate countdown autoc losing time countdown autoc losing time closes the gate partially blocks closings blocks opening blocks closings opens closing stopped open closed 5s after unlock closes 5s after unlock clo...

Page 12: ...UT STOP blocks OPEN A B stop stop blocks OPEN A B PHOTO OP blocks OPEN A B rewers blocks OPEN A B PHOTO CL rewers blocks OPEN A B blocks OPEN A B blocks OPEN A B blocks OPEN A B blocks OPEN A B PHOTO OP CL blocks OPEN A B opens the gate opens partially closes closes blocks closings blocks closings stop until unlock opens stop until unlock opens opens closing stopped open closed Tab 5 5 B mode 5 B ...

Page 13: ...ed open closed Tab 6 6 C mode 6 C mode OPEN_A opens stop opens OPEN_B stop closes closes INPUT STOP blocks OPEN A stop stop blocks OPEN A B blocks OPEN B PHOTO OP blocks OPEN A stop blocks OPEN A PHOTO CL stop blocks OPEN A B blocks OPEN A B PHOTO OP CL blocks OPEN A stop stop blocks OPEN A B blocks OPEN A B opens closing stopped open closed Tab 7 7 P mode 7 PA mode OPEN_A stop rewers OPEN_B stop ...

Page 14: ...ogrammedontheremotecontrolcanbeusedinsteadofLEARNbutton leavesstartthemovementtowardsopening secondpressing oftheearlierchosenbutton theleavesstop LEDLEARNdiodegoesoff 5 6 LearninginEXTENDEDmode This procedure requires more involvement in the process the learning from the fitter than in case of the simplified mode The fitter is able to set slowdown times at opening slowdowns at closing opening and...

Page 15: ...ing leaf2startsslowedmovetowardsclosing tenthpressing leaf2increasesspeedtostandardclosingspeed eleventhpressing leaf2issloweddown twelfthpressing leaf2stops thirteenthpressing leaf1startsslowedmovetowardsclosing fourteenthpressing leaf1increasesspeedtostandardclosingspeed fifteenthpressing leaf1issloweddown sixteenthpressing leaf1stopsandtheprocedureisfinished LEARNLEDdiodegoesoff Inordertosetthe...

Page 16: ...oraerialconnection In the brand new receiver an inside aerial 170 mm long is connected to the terminal To increase the range of the radio remote control it is necessary to connect outside stubby aerial To connect the coaxial cable of the outside aerial to the terminal centre vein of the cable and to the terminal cable screen In order to achievetheoptimumradioreachitisimportanttorememberabout negat...

Page 17: ...he way to the end of the procedure After about 4 sec A diode turns on it means that currently the blocking of remote subscriptionisturnedoff weholdthebuttonallthetime After4consecutivesecondsBdiodeturnson itmeans that the function of remote subscription will be blocked When we release the button kept the card will remember settings and remote subscribing of remote controls will be blocked The proc...

Page 18: ...r memory when we press and hold for more that 15 secondsAandBbuttons CAUTION Format process of the memory card causes irreversible removal of all remote controls and turning off the block of remote subscribing of remote controls 6 9 BoardofradioreceiverEasyRX 1 channelAsignaldiode 2 Achannelbutton 3 channelBsignaldiode 4 Bchannelbutton 5 connectorofthecard 6 channelCsignaldiode 7 Cchannelbutton 8 ...

Page 19: ...alled it is necessary to cause manual disturbance of the OP photocell on the controller board a PHOTO diode should go out 1 Act the same for theCL photocell andOP CL if are installed In sleeping mode when optical crash barriers aren t disturbed signalling PHOTO diodes 1 2 and 3 should shine If it isn t so it means error in photocells operation incorrect connecting not synchronizing the transmitter...

Page 20: ...ng the warranty period there are problems which come because of his fault Broken device should be supplied on customer s expense to the place of purchase and enclose clear and brief description of the breakage The cost of mount dismount is covered by the user The warranty does not cover batteries in the remote controls faults caused by improper usage user self repairs and adaptations lightning str...

Page 21: ...duce the amount of hazardous substances in waste The underlying purpose is to promote the avoidance recovery and risk free disposal of waste DTMSystemherebydeclaresthatthegatecontrollercomplieswithDirective2014 53 EU The full text of the EU Declaration of Conformity is available at the Internet address www dtm pl ...

Page 22: ......

Page 23: ......

Page 24: ...DTM System spółka z ograniczoną odpowiedzialnością spółka komandytowa ul Brzeska 7 85 145 Bydgoszcz Polska http www dtm pl ...

Reviews: