8
Control unit enables to regulate the power of servomotors. Regulation takes place separately for every
servomotor with the help of potentiometers ( respectively FORCE 1 fot the first servomotor and FORCE 2 for the
second servomotor)
If it is necessary to delay the movement of one of the leaves, MOTOR DELAY time is set
(0...15sek.).While OPENING the move of servomotor 2 is delayed and while CLOSING the move of servomotor 1 is
delayed. The delay of the movement is only when the leaf is in the final closing or opening position. The delay
while OPENING is max. 3 sec. even when higher parameter value is set with the help of MOTOR DELAY
potentiometer.
AUTO CLOSE potentiometer allows non-linear regulation of the automatic time of gate closing in the scope from
1 up to 120 seconds. The non-linearity of the regulation is the fact that initial changes of the potentiometer axis
angle give small increase in the autoclosing time, however after exceeding the half of the accessible angle of the
values rotation the delays increase much more quickly, all the way to the maximum value. The scale was drawn for
better understanding.
CAUTION!
Decreasing the operational power of the servomotor has positive influence on safety conditions, as well as
to the vitality of mechanical fittings.
5.4. Przełącznik DIP-SWITCH sekcja MODE - tryb (logika) pracy sterownika EASY B232
DIP-SWITCH MODE section - EASY B232 control unit operation mode (logic)
Below there are operation modes of EASY control unit. It is necessary to analyse the user needs and next
choose appropriate among available.
5.4.1. 1/A mode
Automatic mode, it has function of auto closing the gate after the set time -
maximum 120 seconds. Function of the wicket active, function of photo closing
disabled.
* If after removing an obstacle there are fewer than 5 seconds left to automatic closing then the time of automatic
closing is increased up to 5 seconds.
** When the last move was opening the wicket, it opens the gate.
OUTC
1/A mode
opens closing stopped open
OPEN_A
rewers
OPEN_B
rewers
INPUT STOP
blocks OPEN A/B
stop
stop
PHOTO OP
blocks OPEN A/B
rewers
blocks OPEN A/B blocks opening
PHOTO CL
rewers
PHOTO OP/CL
blocks OPEN A/B
blocks OPEN A/B
closed
opens the gate
opens partially
and close after
and close after
auto-closing time
auto-closing time
closes the gate
Tab. 1
. 1/A mode
closes the
gate/partially
(countdown autoc-
losing time)
closes the
gate/partially
(countdown autoc-
losing time)
auto shutdown
counting time
stopped until the
obstacle removed
auto shutdown
counting time
stopped until the
obstacle removed
closes the
gate/partially
blocks OPEN A/B
stop until unlock,
opens
stop until unlock,
opens
blocks closings
stop