PRORXD Broadcast Receiver User Guide
Commercial in Confidence
Broadcast Solutions, HD/SD Products,
PRORXD
100167
Revision: 7.0
Commercial in Confidence
Page 7-65
No
Property
Range
Description
1
Genlock Mode
Off
External
Internal
Off - Genlock switched off and system is not
locked.
External – Operating with the Genlock source
connected to the external port on the rear of the
receiver. This is usually your station SPG.
Internal – Operating with the receiver’s own
Genlock source built into the unit.
2
Offset Lines
0
Standard dependant. Enables you to apply delay
adjustment.
3
Offset Pixels
0
Standard dependant. Enables you to apply delay
adjustment.
Table 7-20 – Genlock Settings Pane Key
Step 8: Operate the Apply Button Consistently
When you change a parameter on the Control Application it is very important to click the Apply button and
wait for a moment for the changes to be sent to the device.
Frequently personnel change a parameter and then wonder why the device has not changed behaviour.
Always click the Apply button.
Step 9: About the Refresh Button
If the Polling is enabled then the Control Application will poll the device at intervals of two seconds thus it
can update the Transmitter Control Window with the latest configuration changes.
Sometimes, it might be necessary to keep the polling off. To update the Window in this situation it will be
necessary to click the Refresh Button to see the latest changes.
7.8
Setting the Clock
Before you Start
This is necessary:
To have connected your PC to the PRORXD with an IP connection.
To be logged on to the PRORXD unit.
Step 1: Open the Global Settings Tab
1.
Click on the Global Settings tab.
Step 2: Set the Clock
1.
Click the Set Clock button.
2.
The Set Clock dialog opens.
3.
Click the Date box.
4.
The Calendar opens.
5.
Select the date as required.