AEON Family User Guide
Commercial in Confidence
Video, Broadcast
100249
Revision: 1.0
Commercial in Confidence
Page
5-33
Property
Value
Description
Video Pid
32 to 8190
This sets the packet id for the video content in the
Program. The Video PID is listed in the PMT.
These can be edited but should be left to default unless
an advanced user.
Data Pid
32 to 8190
This sets the packet id for the data content in the
Program. The Data PID is listed in the PMT.
These can be edited but should be left to default unless
an advanced user.
Note 1
: The mux bitrate must be equal to or greater than the total bit rate of services and inputs. If the total
bit rate exceeds the mux bitrate the output stream won’t work.
Note 2
: If you set ASI Remux to Relay it disables the video source for that channel. You must switch ASI
Remux Off when you want to reselect a video source.
Streamer Pane
Property
Value
Description
Streaming Mode
Off
UDP
RTSP Unicast
RTSP Multicast
RTP
RTP-Z
Select the streaming mode you wish to operate with.
Streams can be played back using VLC or Domo Video
Player (requires a license).
Note
: RTP-Z is DTC’s compressed RTP. You will need
Domo Video Player to run streams using this protocol.
Base Address
For example:
237.103.227.228
This enables you to change the address used by the unit
for streaming. The default value is random to make sure
different transmitters have different multicast addresses.
Base Port
10000 or above
UDP uses port numbers in the header to direct traffic
around the network.
A good rule is to use numbers above 10000 to avoid
conflict with existing services.
When you set up a port number on several computers on a
network they will all listen for packets directed to that
port.
Record Enable
Set or clear
When you select this box, the video will be recorded to the
built in SD card.